iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual
Issue 2.3
444
4.4.6.8
Personal Group Attribute - PGM 261
Selecting Personal Group Attribute will display the Personal Group Attribute entry page. Enter a valid Personal
Group number to enter the group data.Click
[Save]
button after changing Value.
Enter Group Number: eMG80/100: 1-70 / eMG800: 1-600 / UCP: 1-1200
Figure 4.4.6.8-1 Personal Group Attributes
Table 4.4.6.8-1 PERSONAL GROUP ATTRIBUTES
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
Wake-Up
If this value is set to Overall, all member wake-up follow by master
wake up.
If this value is set to Individual, individual wake-up is worked by
each station.
Individual/
Overall
Individual
Call-Forward
If this value is set to Overall, call forward setting affect to Master
and all members.
If this value is set to Individual, individual Call Forward is worked
by each station.
Individual/
Overall
Overall
Do-Not
Disturb
If this value is set to Overall, DND setting affect to Master and all
members.If this value is set to Individual, individual DND is
worked by each station.
Individual/
Overall
Individual
Linked Pair
Mode
If this value is set to ON, Master and Member Stations are linked
and only one station can be activated.
OFF (Cover Ring), ON (Cover Ring and State Sync.)
Refer to
description
OFF
(Cover Ring)
PAGE/PTT
Receive
If this is set to Overall, PAGE and PTT calls are received by
Master and all members by the Master who is belong to the PAGE
zone and PTT group.
If this is set to Individual, PAGE and PTT calls are received only
by each station who is belong to the PAGE zone and PTT group.
Individual /
Overall
Overall