iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual
Issue 2.3
666
Table C-5 CO LINE DATA
BTN
SUB-MENU
RANGE
DEFAULT
REMARK
12 PROCTOR ON/OFF
1: ON, 0: OFF
OFF
13 WAIT IF VSF BUSY
1: ON, 0: OFF
ON
14 Unused
15 Unused
16 COL RING TONE
1-12
0
0 is Not Available
17 Unused
18 Gain table index
1-3
1
19 Tone table index
1-5
1
20 Digit conversion table index
01-15
01
PGM: 142 - CO/IP Line Attributes II
1
CO Line Name Display
1: ON, 0: OFF
OFF
2
CO Line Name Assign
12 characters
-
Max 12 character, alpha entry
3
Metering Unit
0~6
0
4
Line Drop using CPT
1: ON, 0: OFF
OFF
Not Supported
5
DISA Authorization Code
1: ON, 0: OFF
ON
6
CO Line MOH
0~37
1
0: Refer to System hold,
1: INT Music, 2: EXT music,
3: VSF MOH,
4~8: SLT MOH1~5,
9~37: VSF MOH2~30
7
CO Dial Tone
1: ON, 0: OFF
ON
8
CO Ring Back Tone
1: ON, 0: OFF
OFF
9
CO Error Tone
1: ON, 0: OFF
OFF
10 CO Busy Tone
1: ON, 0: OFF
OFF
11 DISA CO Access
1: ON, 0: OFF
OFF
12 CO Flash Timer
000~300
050
10 msec. Increments
13 Open Loop Detect Timer
00~20
04
100 msec. Increments
14 ICLID Detect Timer
00~20
00
1 sec. Increments
15 SMS OUTGOING
0:Disable
1:Enable
Disable
16 SMS RCV STATION
17 CO Line Dial Tone Source
0: dial tone
1: INT Music,
2: EXT music,
3: VSF MOH,
4~8: SLT MOH1~5,
9~37: VSF MOH2~30
dial tone
18 CO Line Ring Back Tone Source
0: ring back tone
1: INT Music,
2: EXT music,
3: VSF MOH,
4~8: SLT MOH1~5,
9~37: VSF MOH2~30
ring back
tone