10.3 Chime Bell
Description
A station can be configured to activate a Chime at another station. When activated, the
assigned station will receive the Chime Bell tone for the Chime Bell timer. In addition, a Chime
Bell can be configured to activate the External Loud Bell contact.
Operation
To program a Chime Bell Flexible button at a DKT,
1. Press the [TRANS/PGM] button.
2. Press the desired Flexible button.
3. Press the [TRANS/PGM] button
4. Dial ‘*’ 9.
5. Press the [HOLD/SAVE] button.
To activate the Chime Bell,
1. Press Chime Bell button at a station as to activate a Chime Bell.
Consideration
The ring stops when Chime Bell Timer expires.
A muted Chime Bell is used if the receiving station is busy.
Chime Bell is available only to DKTs.
Reference
A. Station User Programming
B. Flexible Buttons
C. External Loud Bell
Admin Programming
Chime Bell Station Pair (PGM184, Flexible button 1)
Assigns the master and receiving Stations
Chime Bell Relay (PGM184, Flexible button2)
Enable activation of the Loud Bell contact when Chime Bell is activated
Chime Bell Timer (PGM184, Flexible button 3)
Sets the duration of the Chime Bell signal
Chime Bell Frequency (PGM184, Flexible button 4)
Defines the tone frequency to use for the Chime Bell