ipLDK-60 Hardware Description and Installation Manual
Issue 2
KSU INSTALLATION
July, 2010
15
3.2.5 Frame Ground Connection
It is very important that the frame of the ipLDK-60 System is grounded. Proper grounding reduces RF noise and
reduces the potential damage from Lightning strikes.
1. Turn the grounding screw counter clockwise to loosen, as shown in Figure 3.2.5.
2. Insert the grounding wire and tighten the screw.
3. Then connect the grounding wire to an appropriate ground source (refer to Caution).
FIGURE 3.2.5 GROUNDING THE KSU
CAUTION—
9
The equipment should be connected to a socket-outlet with a protective ground connection.
9
For ground wire, green-and-yellow insulation is required and using a UL 1015 AWG #18 (1.0mm) or larger
conductor. It is recommended that the ground wire is shorter than 1m (3.28ft).
9
Proper grounding is very important to protect the ipLDK-60 from external noise and to reduce the risk of
electrocution in the event of lightning strike.
9
Be sure to comply with applicable local regulations.