ring_type
Specifies the default ring type for the IP Phone. Ring type
can be a value from 1 to 4.
The default is 1.
alert_ring_type external
Specifies the external ring type for the IP Phone. Ring type
can be a value from -1 to 4:
• -1, Default ring
• 0, ring off.
• 1 ~ 4, ring type 1 to 4 (tone ring),
The default is -1.
dtmf_payload
Sets the DTMF payload type for RFC2833.
Valid values are 96 through 255.
The default is 101.
dtmf_duration
Sets the DTMF duration.
Valid values are 50 through 300 ms.
The default is 120.
cadence0
Sets the ring cadence for calls with undefined in Alert Info
header.
The valid value is a six value time array (on off on off on off).
The valid range is 0 to 30000 milliseconds total time.
The default is 2000-4000-0-0-0-0.
cadence1
Sets the ring cadence for calls with External call in Alert Info
header.
The valid value is a six value time array (on off on off on off).
The valid range is 0 to 30000 milliseconds total time.
The default is 800-400-800-4000-0-0.
cadence2
Sets the ring cadence for calls with Group call in Alert Info
header.
The valid value is a six value time array (on off on off on off).
The valid range is 0 to 30000 milliseconds total time.
The default is 400-200-400-200-800-4000.
cadence3
Sets the ring cadence for calls with Internal call in Alert Info
header.
The valid value is a six value time array (on off on off on off).
The valid range is 0 to 30000 milliseconds total time.
The default is 300-200-1000-200-300-4000
cadence4
Sets the ring cadence for calls with ACD call in Alert Info
header.
The valid value is a six value time array (on off on off on off).
The valid range is 0 to 30000 milliseconds total time.
The default is 500-0-0-0-0-0
cadence5
Sets the ring cadence for calls with priority call in Alert Info
header.
The valid value is an eight value time array (on off on off on
off on off). The valid range is 0 to 30000 milliseconds total
time.
The default is 1500-4500-0-0-0-0-0-0
cadence6
Sets the ring cadence for calls with emergency call in Alert
Info header.
The valid value is an eight value time array (on off on off on
off on off). The valid range is 0 to 30000 milliseconds total
time.
The default is 1500-500-1500-2500-0-0-0-0