ARIA SOHO Version 1 Issue 0.3
ADMIN Programming Manual
June, 2006
26
PGM 142
DESCRIPTION
PROCEDURE
COMMENTS
CO Line MOH
Designates MOH on the CO
Line (refer to VALUES)
+ FLEX6 + 02 (External
Music) + [HOLD/SAVE]
VALUES –
0 = Not Assigned
1 = Internal Music
2 = External Music
3 = VMIB MOH
4-8 = SLT MOH
9 = Hold Tone
PABX CO Dial Tone
If this value is set to YES, PBX
or PABX provides the CO Dial
Tone; otherwise, the LDK
System provides it.
+ FLEX7 + 0 (NO) +
[HOLD/SAVE]
VALUES –
0 = NO (System)
1 = YES (PBX)
PABX CO Ring Back
Tone
If this value is set to YES, PBX
or PABX provides a CO Ring
Back Tone; otherwise, the LDK
system provides it.
+ FLEX8 + 1 (YES) +
[HOLD/SAVE]
VALUES –
0 = NO (System)
1 = YES (PBX)
PABX CO Error Tone
If this value is set to YES, PBX
or PABX provides a CO Error
Tone; otherwise, the LDK
system provides it.
+ FLEX9 + 1 (YES) +
[HOLD/SAVE]
VALUES –
0 = NO (System)
1 = YES (PBX)
PABX CO Busy Tone
If this value is set to YES, PBX
or PABX provides a CO Busy
Tone; otherwise, the LDK
system provides it.
+ 1 (YES) +
[HOLD/SAVE]
VALUES –
0 = NO (System)
1 = YES (PBX)
PABX CO Announce
Tone
If this value is set to YES, PX or
PABX provides a CO Announce
Tone; otherwise, the LDK
system provides it.
+ 1 (YES) +
[HOLD/SAVE]
VALUES –
Default = 0
0 = NO
1 = YES
CO Flash Timer
Designates the length of time
limit for CO Flash. CO Flashing
is available within this timer;
otherwise, the CO Line is
released.
+ 010
(100msec, Range=000-
300) + [HOLD/SAVE]
Open Loop Detect Timer
Designates the time limit for CO
Open Loop.
+ 010
(100msec, Range=000-
300) + [HOLD/SAVE]
Line Length
Used to determine the line
length when the CO Line length
is too variable (SAF only).
+ 1 (LONG) +
[HOLD/SAVE]
VALUES –
0 = SHORT
1 = LONG
DISA Answer Timer
System answers DISA call after
this time.
+ VALUE (1
digit, Range=1-9) +
[HOLD/SAVE]
DISA Delay Timer
This timer is used to delay the
connection of the DTMF
receiver after the DISA line
answers
+ VALUE (1
digit, Range=1-9) +
[HOLD/SAVE]