ARIA SOHO Version 1
Issue 0.2
Feature Description and Operation Manual
June, 2006
Condition
An external contact should be connected to the alarm input.
The alarm contacts should be dry (no voltage/current source connected).
SLT phones cannot receive alarm signals.
Alarm reset can be programmed on a flexible button.
Admin Programming
Alarm Enable (PGM 163 – FLEX1)
Alarm Contact Type (PGM 163 – FLEX2)
Alarm Mode (PGM 163 – FLEX3)
Alarm Signal Mode (PGM 163 – FLEX4)
Station Alarm Attribute (PGM 113 – FLEX10)
2.4.3 Automatic Privacy
Description
Automatic Privacy allows a Station User to suspend automatic privacy for an existing CO Line conversation
without invitation. By default, all conversations that take place on CO Lines, the Intercom, and Conferences are
protected by Automatic Privacy.
NOTE—Admin Programming (PGM 161 – FLEX5) is required to enable or disable this feature.
Operation
If Automatic Privacy is enabled, when pressing a busy CO Line button, a busy tone will be heard.
If Automatic Privacy is disabled, when pressing a buy CO Line button, the Station is connected to the conversation
in progress.
Condition
When Automatic Privacy is disabled, privacy is still activated for Intercom and Conference calls.
A Station can only override a privacy-disabled Station.
The Station will present an intrusion tone when another Station accesses the line.
Admin Programming
Auto Privacy (PGM 161 – FLEX5)
Privacy Warning Tone (PGM 161 – FLEX6)
Override Privilege (PGM 113 – FLEX4)
43