ARIA SOHO Version 1
Issue 0.2
Feature Description and Operation Manual
June, 2006
Saved User database information includes:
- Station Number
- Station Attributes (PGM 111 – 124)
- CO Routing (Ring Assign)
- Hunt Group Membership
- Voice Mail
If the User tries to log-in at another Station without logging-out of a dummy Station, the previous
used Station will return to the dummy state automatically.
The hot desk will automatically log-off if there is no activity at the DKTU within the Auto Log-Out
timer.
The button map of the hot desk will not be changed even tough a User logs-on to a different
type of DKTU (it is recommended that the same type of DKTU is used for the Hot Desk Station).
Only DKTU s (with more than 12 buttons) and WKT s can be used as dummy stations.
The modern associated with the Station cannot log in (PGM 170).
When the system reset happens, all login agents are automatically logged out.
Admin Programming
Dummy Station ON/OFF (PGM 112/B TN23)
Refer to
ARIA SOHO Hardware Description and Installation Manual
, Number of Agents (PGM 250 –
FLEX1)
Refer to
ARIA SOHO Hardware Description and Installation Manual
, Assign Station Number of Agents
(PGM 250 – FLEX2)
Refer to
ARIA SOHO Hardware Description and Installation Manual
, Number of Agents (PGM 250 –
FLEX3)
2.4.30 Analogue CLI Display
Description
The ARIA SOHO System supports the following Type I CID protocol specifications:
Bell core GR-30-CORE & SR-TSV-002476 & ETSI ETS 300 659, ETSI ETS 300 778
Denmark, TDK-TS 900 216
US, BT SIN 227 & SIN 242
Sweden, Telecom specification 8211-A112, Standard SS 63 63 25
Russia CID
Operation
When an incoming CO call is received at a CLCOB line that has a FSK CID detection option board:
1.
The DSP chip on the MBU will detect the FSK CID signal.
2.
The call will be distributed to Stations with CLI.
Condition
If an incoming CO call is assigned to multiple SLT s of a same slot, the CO rings are generated
sequentially with a 1 second interval on the SLT s; CLI is displayed on the SLT after the first
ring.
For CLI display on the SLT, a Ring Phase (PGM 182 - FLEX4) more than 4 seconds is
recommended.
If the ring phase is less than 4 seconds, some of the SLT s will not receive CLI display signal.
68