2.5.3 Automatic Call Release
Description
When a station does not initiate dialing on an outgoing CO line or receive no answer on an intercom
call, the system will return the CO line or the called station to idle based on the assigned Auto Release
Timer(ADMIN program 180 – FLEX 14). If on the speaker phone or monitor mode, the station will
return to idle, otherwise the station will receive error tone if using the handset.
Condition
1. Intercom call in H/P mode(see Ref.1) is regarded that it is answered and Station Auto Release is
not activated.
2. When the Automatic Release time is assigned to 0, Auto Call Release is not activated.
3. While making a call without lifting handset and Auto Release timer is expired, the call is canceled
and the station will go idle state automatically.
4. While making a call with lifting handset and the Auto Release timer is expired, the call is canceled
and the station will receive error tone.
Reference
1. Intercom Signal Mode : 2.4.14
Admin Programming
n
Automatic CO Release Timer
4.5.1.14 (PGM 180 – FLEX 14)
n
Station Auto Release Timer
4.5.3.5 (PGM 182 – FLEX 5)