IPECS Release 5
Hardware Description & Installation
Issue 5.0
95
BGM
External BGM or Internal MOH is active
S1 Reserved
S2
Steady On: WAN disconnected
Flashing: WAN connected
Note 1: An optional CMU (Call Metering Unit) can be installed according to the relevant national
regulations, refer to the RSGM install guide and section 4.5.4.
Wiring Connectors
Before wiring any of the Modules, first connect the “ ” screw on the back of the Module to a
known ground, refer to section 4.5.1.4.
On the front of the RSGM, there are three (3) LAN RJ-45 type connectors. These connectors
should be wired to the appropriate LAN point.
¾
Wire the “WAN” port to a 10/100 Base-T switch, broadband modem or router.
¾
Tag or number wiring for maintenance.
¾
Wire “LAN” port to an external PC.
¾
Tag or number wiring for maintenance.
¾
Wire “IPKTS” port to an external LIP Phone.
¾
Tag or number wiring for maintenance
Before connecting an iPECS Phone to the RSGM IPKTS port, check the LAN
POWER switch on the rear panel of the RSGM.
On the rear panel, there are four (4) RJ-11 connectors. The upper most connector is for an analog
CO line, which should be wired to the telephone company termination point. For detailed
connection, see Figure 4.5.16-3.
¾
Wire the RJ-11 to a CO Line at the PSTN termination point.
¾
Tag or number wiring for maintenance.
The 2
nd
RJ-11 connector is for an SLT, which should be wired to the SLT termination point as
detailed in Figure 4.5.16-3.
¾
Wire the RJ-11 to a SLT device.
¾
Tag or number wiring for maintenance.
The 3
rd
and 4
th
RJ-11 connectors are used for external alarm/door bell input, external BGM input
and two (2) dry relay contacts. For detailed connection, see Figure 4.5.16-3.
¾
Wire each RJ-11 for miscellaneous connections as shown in Figure 4.5.16-3.
¾
Tag or number wiring for maintenance.