ERROR
SYMPTOM CAUSE
8
9
10
• MAIN PWB ASSEMBLY is out of order
☞
Replace the MAIN PWB ASSEMBLY
• Winding in the STATOR ASSEMBLY is short-circuited.
☞
Replace the STATOR ASSEMBLY
• “ ” is dispplayed during a high spin
☞
Replace the LEAD WIRE ASSEMBLY (MOTOR)
• The connector in the LEAD WIRE ASSEMBLY is not connected to
the connnector of STATOR ASSEMBLY
☞
Reconnect or repair the connector
• The hall sensor is out of order/defective.
☞
Replace the STATOR ASSEMBLY
• The Dry Heater is out of order
☞
Replace the Dry Heater
• The Connector of the Dry Heater is not connected properly to the
connector in the Main PWB ASSEMBLY
☞
Reconnect or repair the connector
• The Dry fan motor is out of order
☞
Replace the fan Motor.