- 7 -
SPECIFICATIONS
Note :
Specification and others are subject to change without notice for improvement.
F
Scope
This specification can be applied to all the television related to
MC-049C Chassis.
F
Test and Inspection Method
1) Capacity : Follow LG electronics TV testing Standard.
2) Another Required Standard
- EMI : Following CE Standard (EN55020, EN55013)
- Safety : Following CB Standard (EN55013)
F
Requirement for Test
Testing for standard of each par must be followed in below
condition.
1) Temperature : 20
± 5°C
(But, CST must be tested 40
± 5°C . Humidity : 50%)
2) Relative Humidity : 65
± 10%
3) Power : Standard input Voltage (110-240V~, 50/60Hz)
4) Measurement must be performed after heat-run more than
20min.
5) Adjusting Standard for this chassis is followed a special
standard.
No
1
2
3
4
5
6
7
8
Item
Receiving System
Receiving Channel
Input Voltage
Market
Screen Size
Tuning System
Operating Environment
Storage Environment
Remark
For EU/ For Non EU
For EU/ For Non EU
NTSC-M (Multi - model)
Non EU
EU
Initial Model -> for EU
SUPER SLIM
200 PR. (OPTION)
Specification
1) PAL/SECAM BG
2) PAL/SECAM DK
3) PAL I/I
4) NTSC M
5) SECAM-L/L’
6) NTSC 4.43(AV)
1) VHF : E2 ~ E12
UHF : E21 ~ E69
CATV : S1 ~ S20
HYPER : S21 ~ S41
2) L/L’ : B,C,D
3) VHF : 02 ~ 13
UHF : 14~ 69
CATV : 02 ~ 71
110-240V~, 50/60Hz
240V~, 50Hz
EU,CIS, China, Asia, Africa
F 21”
FVS 100Program
1) Temp. : 0 ~ 45 deg
2) Humidity: 85% under
1) Temp. : -20 ~ 60 deg
2) Humidity: 85% under
F
General Specification
Summary of Contents for 21FS2ALX
Page 16: ... 17 SIDE A V ...
Page 18: ...MEMO 19 ...
Page 19: ... 20 EXPLODED VIEW 112 913 170 150 153 943 400 300 520 P801 330 310 320 600 121 120 105 ...
Page 27: ...P NO 3854VA0204A S1 2004 12 15 ...