COMMER
CIAL
MODE
SETUP
98
COMMERCIAL MODE SETUP
CLONING LEARNING SETUP
Learning the Master TV Setup
Instructions for the Clone Programmer to Learn the Master TV Setup
Use MPI Cable to Connect LT2002 Clone
Programmer to Master TV MPI Port
If there is a good connection, “THE CLONE HAS CONTROL OF TV”
message will appear. Press any key on the Installer remote.
Learn Setup from Master TV
Press 1 to select the “LEARN FROM TV” option, then press
ON/OFF, POWER, or ENTER to go to the Memory Bank
Selection Menu. Pick the Memory ”Bank” you want to store
the master TV’s setup in by pressing either Channel key
repeatedly to choose Memory 1, 2 or 3. (If you choose a
Memory “Bank” that has a master device’s setup programmed
into it, that setup will be overwritten by the new master TV’s
setup.) Once the Clone memory bank is selected, press
ON/OFF, POWER, or ENTER. The Clone memory bank you
have selected will be shown. Press ON/OFF or POWER to
begin copying the master TV’s setup.
Set the Clock (Optional)
Set the time on a Master TV’s Clock. (If the time has already
been copied from a TV into the Clone programmer, you can
set a master TV’s clock by copying the time from the Clone
programmer.) The Clone Programmer can copy the current
time to both a master TV and to the Clone’s internal clock;
accurate to within one minute. (Another reason that the Clone
programmer should be equipped with fresh, high-quality alka-
line batteries, is for it to keep the time as accurately as possi-
ble.)
Since the Clone Programmer’s time cannot be set directly, the
current time needs to be copied from a Zenith/LG TV
equipped with M.P.I. input capability.
After the time is copied to the Clone programmer, the current
time can then be transferred to another TV. (This can be a
master TV, or another TV which has already had the features
set up.)
LT2002 Clone Programmer Communication
Problems
• A slow flashing green light indicates there are
communication problems between the TV and
the LT2002 clone programmer. If this is the
case, check for a damaged cable, poor con-
tacts, or other connection troubles.
• If the status indicator is red, the programmer
batteries are low and should be replaced.
Install 4 high-quality alkaline AA batteries.
THE CLONE HAS CONTROL OF THE TV
THE CLONE IS VERSION
XX
THE TV IS VERSION
XX
THE SW IS REVISION
XX
CLONE CLOCK=
XX:XX
TV
CLOCK=
XX:XX
-PRESS ANY KEY TO CONTINUE.
-DISCONNECT CLONE WHEN DONE.
CLONE SELECTION MENU
(1) LEARN FROM TV
(2) TEACH TO TV
(3) SET CLONE CLOCK FROM TV
(4) SET TV CLOCK FROM CLONE
(5) DISPLAY TV SETUP
(6) DISPLAY CLONE SETUP
-TO CHANGE MENU ITEMS, PRESS
CHANNEL KEYS OR DIGITS.
-TO EXECUTE ITEM, PRESS ON/OFF,
POWER, OR ENTER
This menu should appear by itself after
the LT2002 is connected to the TV MPI
port.
This menu should appear after any key is
pressed on the Installer remote.