background image

- 4 -

LGE Internal Use Only

Copyright  © 

 ~ 

 LG Electronics. Inc. 

All right reserved. 

Only for training and service purposes

CAUTION: Before servicing receivers covered by this service 

manual and its supplements and addenda, read and follow the 

SAFETY PRECAUTIONS on page 3 of this publication.

NOTE: If unforeseen circumstances create conflict between the 

following servicing precautions and any of the safety precautions on 

page 3 of this publication, always follow the safety precautions. 

Remember: Safety First.

General Servicing Precautions

1.  Always unplug the receiver AC power cord from the AC power 

source before;

a.  Removing or reinstalling any component, circuit board 

module or any other receiver assembly.

b.  Disconnecting or reconnecting any receiver electrical plug or 

other electrical connection.

c.  Connecting a test substitute in parallel with an electrolytic 

capacitor in the receiver.

 

CAUTION: A wrong part substitution or incorrect polarity 

installation of electrolytic capacitors may result in an 

explosion hazard.

2.  Test high voltage only by measuring it with an appropriate high 

voltage meter or other voltage measuring device (DVM, 

FETVOM, etc) equipped with a suitable high voltage probe.

  Do not test high voltage by "drawing an arc".

3.  Do not spray chemicals on or near this receiver or any of its 

assemblies.

4. Unless specified otherwise in this service manual, clean 

electrical contacts only by applying the following mixture to the 

contacts with a pipe cleaner, cotton-tipped stick or comparable 

non-abrasive applicator; 10% (by volume) Acetone and 90% (by 

volume) isopropyl alcohol (90%-99% strength)

  CAUTION: This is a flammable mixture.

  Unless specified otherwise in this service manual, lubrication of 

contacts in not required.

5.  Do not defeat any plug/socket B+ voltage interlocks with which 

receivers covered by this service manual might be equipped.

6.  Do not apply AC power to this instrument and/or any of its 

electrical assemblies unless all solid-state device heat sinks are 

correctly installed.

7.  Always connect the test receiver ground lead to the receiver 

chassis ground before connecting the test receiver positive 

lead.

  Always remove the test receiver ground lead last.

8.  Use with this receiver only the test fixtures specified in this 

service manual.

  CAUTION: Do not connect the test fixture ground strap to any 

heat sink in this receiver.

Electrostatically Sensitive (ES) Devices

Some semiconductor (solid-state) devices can be damaged easily 

by static electricity. Such components commonly are called 

Electrostatically Sensitive (ES) Devices. Examples of typical ES 

devices are integrated circuits and some field-effect transistors and 

semiconductor "chip" components. The following techniques 

should be used to help reduce the incidence of component 

damage caused by static by static electricity.

1.  Immediately before handling any semiconductor component or 

semiconductor-equipped assembly, drain off any electrostatic 

charge on your body by touching a known earth ground. 

Alternatively, obtain and wear a commercially available 

discharging wrist strap device, which should be removed to 

prevent potential shock reasons prior to applying power to the 

unit under test.

2.  After removing an electrical assembly equipped with ES 

devices, place the assembly on a conductive surface such as 

aluminum foil, to prevent electrostatic charge buildup or 

exposure of the assembly.

3.  Use only a grounded-tip soldering iron to solder or unsolder ES 

devices.

4.  Use only an anti-static type solder removal device. Some solder 

removal devices not classified as "anti-static" can generate 

electrical charges sufficient to damage ES devices.

5.  Do not use freon-propelled chemicals. These can generate 

electrical charges sufficient to damage ES devices.

6.  Do not remove a replacement ES device from its protective 

package until immediately before you are ready to install it. 

(Most replacement ES devices are packaged with leads 

electrically shorted together by conductive foam, aluminum foil 

or comparable conductive material).

7.  Immediately before removing the protective material from the 

leads of a replacement ES device, touch the protective material 

to the chassis or circuit assembly into which the device will be 

installed.

  CAUTION: Be sure no power is applied to the chassis or circuit, 

and observe all other safety precautions.

8.  Minimize bodily motions when handling unpackaged 

replacement ES devices. (Otherwise harmless motion such as 

the brushing together of your clothes fabric or the lifting  of your 

foot from a carpeted floor can generate static electricity 

sufficient to damage an ES device.)

General Soldering Guidelines

1.  Use a grounded-tip, low-wattage soldering iron and appropriate 

tip size and shape that will maintain tip temperature within the 

range or 500 ˚F to 600 ˚F.

2.  Use an appropriate gauge of RMA resin-core solder composed 

of 60 parts tin/40 parts lead.

3.  Keep the soldering iron tip clean and well tinned.

4.  Thoroughly clean the surfaces to be soldered. Use a mall wire-

bristle (0.5 inch, or 1.25cm) brush with a metal handle.

  Do not use freon-propelled spray-on cleaners.

5.  Use the following unsoldering technique

a.  Allow the soldering iron tip to reach normal temperature.

  (500 ˚F to 600 ˚F)

b.  Heat the component lead until the solder melts.

c.  Quickly draw the melted solder with an anti-static, suction-

type solder removal device or with solder braid.

  

CAUTION: Work quickly to avoid overheating the circuit 

board printed foil.

6.  Use the following soldering technique.

a.  Allow the soldering iron tip to reach a normal temperature 

(500 ˚F to 600 ˚F)

b.  First, hold the soldering iron tip and solder the strand against 

the component lead until the solder melts.

c.   Quickly move the soldering iron tip to the junction of the 

component lead and the printed circuit foil, and hold it there 

only until the solder flows onto and around both the 

component lead and the foil.

 

CAUTION: Work quickly to avoid overheating the circuit 

board printed foil.

d.   Closely inspect the solder area and remove any excess or 

splashed solder with a small wire-bristle brush.

SERVICING PRECAUTIONS

Summary of Contents for 24LH4830

Page 1: ... this Service Manual is STRICTLY PROHIBITED unless you have obtained the prior written consent of the LG Electronics entity from which you received this Service Manual The material covered by this prohibition includes without limitation any text graphics or logos in this Service Manual Copyright 2016 2017 LG Electronics Inc All rights reserved Only training and service purposes CONFIDENTIAL MFL691...

Page 2: ... Electronics Inc All right reserved Only for training and service purposes CONTENTS CONTENTS 2 SAFETY PRECAUTIONS 3 SERVICING PRECAUTIONS 4 SPECIFICATION 6 SOFTWARE UPDATE 9 BLOCK DIAGRAM 10 EXPLODED VIEW 11 TROUBLESHOOTING GUIDE APPENDIX ...

Page 3: ... the instrument AC plug removed from AC source connect an electrical jumper across the two AC plug prongs Place the AC switch in the on position connect one lead of ohm meter to the AC plug prongs tied together and touch other ohm meter lead in turn to each exposed metallic parts such as antenna terminals phone jacks etc If the exposed metallic part has a return path to the chassis the measured re...

Page 4: ...n your body by touching a known earth ground Alternatively obtain and wear a commercially available discharging wrist strap device which should be removed to prevent potential shock reasons prior to applying power to the unit under test 2 After removing an electrical assembly equipped with ES devices place the assembly on a conductive surface such as aluminum foil to prevent electrostatic charge b...

Page 5: ...e solder joints of the two original leads If they are not shiny reheat them and if necessary apply additional solder Fuse and Conventional Resistor Removal Replacement 1 Clip each fuse or resistor lead at top of the circuit board hollow stake 2 Securely crimp the leads of replacement component around notch at stake top 3 Solder the connections CAUTION Maintain original spacing between the replaced...

Page 6: ... must be operated for about 5 minutes prior to the adjustment 3 Test method 1 Performance LGE TV test method followed 2 Demanded other specification Safety UL CSA IEC specification EMC FCC ICES IEC specification NOTE Specifications and others are subject to change without notice for improvement 4 General Specification No Item Specification Remarks 1 Receiving system ATSC NTSC M 64 256 QAM 2 Availa...

Page 7: ...V 720P 6 1280 720 44 96 59 94 74 176 HDTV 720P 7 1920 1080 33 75 60 00 74 250 HDTV 1080I 8 1920 1080 33 72 59 94 74 176 HDTV 1080I 9 1920 1080 67 50 60 00 148 500 HDTV 1080P 10 1920 1080 67 43 59 94 148 352 HDTV 1080P 11 1920 1080 27 00 24 00 74 250 HDTV 1080P 12 1920 1080 26 97 23 97 74 176 HDTV 1080P 13 1920 1080 33 75 30 00 74 250 HDTV 1080P 14 1920 1080 33 71 29 97 74 176 HDTV 1080P No Item EA...

Page 8: ... WUXGA Reduced Blanking FHD only HDMI DTV 1 640 480 31 46 59 94 25 125 SDTV 480P 2 640 480 31 50 60 00 25 125 SDTV 480P 3 720 480 15 73 59 94 13 500 SDTV 480I Spec out but display 4 720 480 15 75 60 00 13 514 SDTV 480I Spec out but display 5 720 480 31 47 59 94 27 00 SDTV 480P 6 720 480 31 50 60 00 27 027 SDTV 480P 7 1280 720 44 96 59 94 74 176 HDTV 720P 8 1280 720 45 00 60 00 74 25 HDTV 720P 9 19...

Page 9: ...lly Download 3 Show the message Copying files from memory 4 Updating is starting 5 Updating Completed The TV will restart automatically 6 If your TV is turned on check your updated version and Tool option explain the Tool option next stage If downloading version is more high than your TV have TV can lost all channel data In this case you have to channel recover if all channel data is cleared you d...

Page 10: ...com I2C 3 IR KEY HDMI MUX LVDS USB SPDIF OUT ETHERNET USB1 OCP 1 5A HDMI1 HDMI2 ARC REAR R E A R Optical Digital Audio out LAN SYSTEM EEPROM 256Kb 30P eMMC 5 0 4GB DDR3 1600 X 16 256MBx2EA I2C 1 X_TAL 24MHz WIFI Built in SUB ASSY USB_WIFI Tuner AV Component CVBS Y Pb Pr L R SIDE TU_CVBS TU_SCL SDA RS 232C SVC Only Tx Rx X_TAL 32 768KHz IR KEY TU_SIF SIFP I2C_2 ...

Page 11: ...ty related characteristics These parts are identified by in the EXPLODED VIEW It is essential that these special safety parts should be replaced with the same components as recommended in this manual to prevent Shock Fire or other Hazards Do not modify the original design without permission of manufacturer IMPORTANT SAFETY NOTICE 300 200 120 900 401 540 910 831 305 541 832 400 510 LV1 A2 730 570 ...

Page 12: ......