60
Plasma Fall 2008 42PG20
Very little alteration to the picture, the wave form indicates a
distorted
Vset UP
. The peek widens due to the
Vset UP
peeking too quickly.
The center begins to wash out and arc due to
Vset UP
Peeking too late and alters the start of the
Vset DN
phase.
Panel Waveform Adjustment
Ramp (Vset UP) too high
Ramp (Vset UP) too low
V Set Up Too High or Low
V Set Up Too High or Low
Vset UP
swing is Minimum 150vP/P Max 220vP/P