12. AREA OPTION
12-1. Using DFT(Auto)
PC (for communication through RS-232C) ==> UART Baud
rate : 115200 bps
Command : ah 00 00 DATA(Area Number(hexadecimal))
12-2. Setting Manual
Press ADJ R/C In-start key and select 1.AREA OPTION,
Select Model Number by using
F
/
G
(VOL +/-) in accordance
with destination
12-3. Outgoing condition Configuration
- After all function test, press IN-STOP Key by SVC Remote
controller. And Make Ship Condition.
- When pressing IN-STOP key by SVC remocon, Red LED
are blinked alternatively. And then Automatically turn off.
(Must not AC power OFF during blinking)
12-4. Internal pressure
Confirm whether is normal or not when between power
board's ac block and GND is impacked on 1.5kV(dc) or
2.2kV(dc) for one second
13. Default Service option.
13-1. ADC-Set
.
V
R-Gain adjustment Value (default 128)
V
G-Gain adjustment Value (default 128)
V
B-Gain adjustment Value (default 128)
V
R-Offset adjustment Value (default 64)
V
G-Offset adjustment Value (default 64)
V
B-Offset adjustment Value (default 64)
13-2. White balance.
CENTER (DEFAULT)
MAX
Cool
Mid
Warm
R Gain
184
192
192
255
G Gain
189
184
150
255
B Gain
192
161
128
255
R Cut
128
128
128
255
G Cut
128
128
128
255
B Cut
128
128
128
255