10
INSTALLATION OF INDOOR
ENGLISH
Wiring Connection
• Open the control box cover and connect the
Remote controller wiring and Indoor power
wires.
• Remove the control box cover for electrical
connection between the indoor and outdoor
unit.
• Use the cord clamper to fix the wiring.
CAUTION
The power wiring connected to the out-
door unit should be complied with the fol-
lowing specifications (This equipment
shall be provided with a cord set comply-
ing with the national regulation).
The connecting wiring connected to the
indoor and outdoor unit should be com-
plied with the following specifications
(This equipment shall be provided with a
wiring set complying with the national
regulation).
If the supply wiring is damaged, it must
be replaced by a special wiring or assem-
bly available from the manufacturer of its
service agent.
!
CAUTION
The Power cord connected to the unit
should be selected according to the fol-
lowing specifications.
Precautions when laying power wiring
Use round pressure terminals for connec-
tions to the power terminal block.
When none are available, follow the in-
structions below.
• Do not connect wiring of different thick-
nesses to the power terminal block.
(Slack in the power wiring may cause
abnormal heat.)
• When connecting wiring which is the
same thickness, do as shown in the fig-
ure below.
!
WARNING
!
Make sure that the screws of the terminal
are free from looseness.
20 mm
GN/YL
Capacity (kW)
5.0
7.0
12.5
13.4
AREA(mm
2
)
2.5
6.0
NORMAL CROSS-SECTIONAL AREA
20 mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 0.75 mm
2
Round pressure terminal
Power wiring