Functions
Parts Name
Inverter compressor
Constant velocity compressor
Inverter fan motor
Outdoor EEV
Excessive cold EEV
Liquid injection
Valve(Inv.)
Liquid injection
Valve(Con.)
Hot gas bypass
valve
Square Junction valve
Outdoor check valve
Inverter high pressure S/W
Constant velocity high pressure S/W
High pressure sensor
Low pressure sensor
Heat exchanger temperature sensor
Inverter discharger temperature sensor
Constant velocity discharger temperature sensor
Air temperature sensor
Suction temperature sensor
Liquid tube temperature sensor
Excessive cold outlet temperature sensor
Excessive cold inlet temperature sensor
Discharge check valve
Symbol
INV.
CON.
IMT
OEEV
SEEV
LINV
LCON
HGV
4 WAY
OCHK
HSINV
HSCON
HPS
LPS
THEX
TINV
TCON
TAIR
TSUC
TLIQ
TSOUT
TSIN
Check solenoid Valve
CSOL
DCHK
Major Function
Operated up to 30Hz~100Hz by inverter operation. Pressurize high
temperature, low pressure refrigerant to high temperature, high
pressure.
Operated cold/heat load with assembly with inverter compressor.
Adjust outdoor wind quantity while varying the outdoor fan by 0~60Hz.
Adjust flow quantity depending on overheat level of refrigerant in the
outdoor side in heat status.
Adjust flow quantity depending on overheat level of the outlet of the
excessive cold heat exchanger in cold status.
Prevent overheat of the compressor by supplying liquid refrigerant
after opening the valve when discharge temperature of the compressor
rises.
Stabilize the system by high pressure gas to the low pressure part
after opening when bypass and low pressure of refrigerant rapidly
reduces to less than the valve valve.
Cut-off the outdoor heat exchanger with the evaporator or condenser
depending on operation of the indoor unit.
Used to obtain flow quantity of refrigerant in cold condition.
Mechanically stop the compressor where the compressor rises to the
high pressure limit valve due to abnormal operation.
Measure high pressure of the system.
Measure low pressure of the system.
.
Used for control by measuring temperature of the outdoor heat
exchanger.
Used for protecting and controlling the compressor by measuring
discharger temperature.
Measure outdoor temperature.
Stabilize the system by high pressure gas to the low pressure part
after opening when bypass and low pressure of refrigerant rapidly
reduces to less than the valve.
Used for controlling excessive heat level by measuring refrigerant
temperature of the suction pipe.
Used for controlling excessive cold level by measuring refrigerant
temperature of the liquid pipe.
Used for controlling excessive heat level by measuring outlet
temperature of the excessive cold circuit.
Used for controlling excessive heat level by measuring outlet
temperature of the excessive cold circuit.
Prevent reverse flow of high pressure refrigerant into the compressor.
2. Functions
2.1 8HP/10HP/12HP/14HP Parts Function