- 33 -
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
3. Operation Detail
■
Auto Swing Control
• This function is to swing the louver up and down automatically.
■
Soft-Dry Operation
• The indoor fan speed is automatically set to the low, so the shift of the indoor fan speed is impossible because of
already being set to the best speed for Dry Operation by microcontroller control.
■
Cooling Mode Operation
• When selecting the Cooling(
) Mode Operation, the unit will operate according to the setting by the remote con-
troller and the operation diagram is as following
(1) The function of main control
Operation Detail
Thermal ON
Thermal OFF
Indoor Unit mode
ST+0.5
ST-0.5
2TH (Remo.+Indoor)
To be selected higher temperature
To be selected higher temperature
contrast Indoor Unit and Remo.
contrast Indoor Unit and Remo.
Remo. Mode
ST+0.5
ST-0.5
Intake Air Temperature
Thermo. ON
(SET TEMPE0.5°C)
Thermo. OFF
(SET TEMPERATURE -0.5°C)
More than
More than
3 minutes
3 minutes
Selected
Selected
Selected
Speed
Speed
Speed
INDOOR FAN
Low Low
Summary of Contents for ARNU07GB1G1