MULTI V
Modular Heat Pump
Product Data
2. Specifications
System Specifications
Module Specifications
HP
5
Model Name
Set
ARUN050LMS0
Compressor Module
ARUN050LMC0
Heat Exchanger Module
ARUN050GME0
Capacity
Cooling* (Rated)
kW
14.0
Btu/h
47,800
Heating* (Rated)
kW
14.0
Btu/h
47,800
Heating* (Max.)
kW
16.0
Btu/h
54,600
Input
Cooling* (Rated)
kW
4.12
Heating* (Rated)
kW
3.59
Heating* (Max.)
kW
4.32
EER
Based on Rated capacity
3.40
COP
Based on Rated capacity
3.90
Based on Max. capacity
3.70
Power Factor
Rated
-
0.93
Number of maxmum connectable indoor units
10
HP
5
Model Names
Compressor Module
Heat Exchanger Module
ARUN050LMC0
ARUN050GME0
Casing Color
Morning Gray
Galvanized Steel Plate
Dimensions
(W × H × D)
Net
mm
580 × 700 × 500
1,562 × 460 × 688
Shipping
mm
618 × 833 × 564
1,806 × 537 × 825
Weight
Net
kg
70.0
89.0
Shipping
kg
75.0
101.0
Compressor
Type
Hermetic Motor Compressor
-
Piston Displacement
cm³/rev
31.6
-
Number of Revolution
rev/min
3,600
-
Motor Output
W
3,200
-
Starting Method
DC Inverter Starting
-
Oil Type
FVC68D (PVE)
-
Heat Exchanger
-
Wide Louver Plus
Fan
Type
-
Sirocco Fan
Motor Output × Number
W
-
400 × 2
Air Flow Rate (Rated)
m³/min
-
60
ft³/min
-
2,542
Drive
-
Direct
External Static
Pressure
Nominal (Rated, Factory Set)
mmAq(Pa)
-
3 (29)
Max.
mmAq(Pa)
-
16 (157)
Pipe Connctions
Liquid
mm(inch)
Ø 9.52(3/8) to IDU
Ø 12.7(1/2) to Comp. Module
Gas
mm(inch)
Ø 15.88(5/8) to IDU
Ø 19.05(3/4) to Comp. Module
Drain
mm(inch)
-
25(1)
Sound Pressure
Level
Cooling (Rated)
dB(A)
45
45
Heating (Rated)
dB(A)
45
45
Sound Power Level
dB(A)
-
-
Protection Devices
High pressure protection
-
High pressure sensor
-
Compressor/Fan
-
Over-heat protection
Fan driver overload protector
Inverter
-
Over-heat protection
Over-current protection
-
Communication Cable (VCTF)
No.×mm²
2C × 1.0 ~ 1.5 to IDU
2C × 1.0 ~ 1.5 to Comp. Module
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length and Difference of Elevation :
– Heat Exchanger Module ~ Compressor Module = 5m
– Compressor Module ~ Indoor Unit = 7.5m
– Difference of Elevation (Heat Exchanger Module~ Compressor Moduler ~ Indoor Unit) is Zero.
6. The maximum combination ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)
Summary of Contents for ARUN050GME0
Page 1: ...Modular Heat Pump R410A 50Hz 5CVD0 01A P No MFL67474053 ...
Page 2: ...MULTI V S Modular Heat Pump General information Product Data Installation Guide ...
Page 11: ...MULTI V Modular Heat Pump 3 Dimensions 6 Product Data GG B8 Chassis ARUN050GME0 ...
Page 27: ...22 MULTI V Modular Heat Pump Product Data 10 Wiring Diagrams ARUN050LMC0 ARUN050GME0 ...