17
Error Code
• Temperature sensor failure
• Turn off the dryer and call for
service.
tE
• Humidity Sensor failure.
• Turn off the dryer and call for
service.
HS
• House fuse is blown, circuit breaker has
tripped, or power outage has occurred.
•
Check the power supply or the
connection of power cord to the
terminal block. Refer to the Connecting
Electric Dryers section of this manual
for complete instructions.
PS , PF
or
nP
Possible Causes
Solutions
Installation test (Exhaust check) (cont.)
• Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
Check the Error Code before you call for service
•
Reset circuit breaker or replace fuse.
Do not increase the fuse capacity.
If the problem is a circuit overload,
have it corrected by a qualified
electrician.
Check the duct condition
If the test displays FLOW SENSE, check the exhaust system for
restrictions and damage. Repair or replace the exhaust system as
needed.
NOTE
When the dryer is first insralled, this test should be performed to
alert you to any existing problems with the exhaust duct in your
home. However, since the test performed during normal
operation provides more accurate information on the condition
of the exhaust duct than does the installation test, FLOW SENSE
displayed during the two tests may not be the same.
Do not interrupt the test cycle, as this could result in the wrong
results.
Even if FLOW SENSE is not displayed during the test cycle, some
restrictions may still be present in the exhaust system.
Refer to the Venting the Dryer section of this manual for complete
exhaust system and venting requirements.
Restricted or blocked airflow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed
transition duct
Too many elbows or
exhaust too long
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or restricted.
Crushed or
damaged
exhaust