1. Remove the cabinet. (Refer to section 3.1.3)
2. Remove a screw or a nut which fastens the
terminal cover
3. Disconnect the lead wire from the overload
protector or P.T.C. assembly.
4. Remove the overload protector or P.T.C. assembly.
(See Figure 16)
5. Replace the component by referring to the removal
procedure above.
3.2.10 COMPRESSOR
1. Remove the cabinet. (Refer to section 3.1.3)
2. Discharge the refrigerant by using a refrigerant
Recovery System.
3. After purging the unit completely, unbrace the
suction and discharge tubes at the compressor
connections.
4. Remove the nuts and washers which fasten the
compressor. (See Figure 16)
5. Remove the compressor. (See Figure 16)
6. Replace the component by referring to the removal
procedure above.
3.2.11 POWER CORD ASSEMBLY
1. Remove the cabinet. (Refer to section 3.1.3)
2. Remove a screw which fastens the earth wire of the
power cord assembly. (See Figure 17)
3. Disconnect the lead wire from terminal block and
micro switch assembly.
4. Remove the power cord assembly. (See Figure 17)
5. Replace the component by referring to the removal
procedure above.