54
TROUBLESHOOTING
Problem
Possible Cause
Solutions
indicator light is on
during the drying cycle
Water supply error.
•
Check steam feeder drawer:
(1) Make sure the steam feeder is filled with
water to the MAX line.
(2) Make sure the steam feeder is seated
properly and the drawer is fully closed.
(3) Turn the dryer off then restart the
STEAM CYCLE.
Do not use distilled water; the water level
sensor in the steam generator will not work.
Pump not working.
•
Unplug dryer and call for service.
The display shows
The duct work is about 75%
- 95% blocked.(“d75”, “d80”,
“d90” or “d95” error code is
displayed for 2 hours only)
•
Do not use the dryer until the exhaust
system has been cleaned and/or repaired.
Using the dryer with a severely restricted
exhaust is dangerous and could result in a
fire or other property damage.
Check the outside dryer vent while the
dryer is operating to make sure there is
strong airflow.
If the exhaust system is extremely long,
have it repaired or rerouted.
House exhaust system
blocked.
•
Keep the area around the dryer clean and
free of clutter.
Check vent hood for damage or lint
clogging.
Make sure the area around the vent hood
is clear.
indicator light is on during the
drying cycle
Lint filter not cleaned properly.
•
Remove the lint from the filter before
every load. With the lint removed, hold
the filter up to a light to see if it is dirty or
clogged. If it looks dirty, follow the cleaning
instructions. With some loads that produce
high amounts of lint, it may be necessary to
clean the filter during the cycle.