1 1
Part 3
INITIAL STEPS FOR INSTALLING YOUR DRYER
In addition to the following warnings, please refer
to manual section on Exhaust Requirements and
Maintenance.
IMPORTANT:
To reduce the risk of
fire, combustion, and gas accumulation, the dryer
must be vented to the outdoors. Please follow the
instructions (and all others in this manual) very
carefully.
• Do not use Plastic or thin foil duct.
• Use 4" (10.2 cm) diameter rigid or Semi-rigid
metal duct (note: venting materials are not
supplied with the dryer, and you should obtain the
venting materials necessary for proper installation)
• Position the Dryer such that the exhaust duct run is
as short as possible.
•
Clean old ducts before installing this dryer
• The male end of each section of exhaust duct must
point away from the dryer
• Use as few elbow joints as possible.
• Use duct tape on all duct joints
• Insulate ductwork that runs through unheated
areas in order to reduce condensation and lint
build-up on pipe walls.
•
PLEASE BE AWARE THAT FAILURE TO
EXHAUST THE DRYER CORRECTLY WILL
VOID THE DRYER’S WARRANTY.
WARNING!
• Use a heavy metal vent.
• Do not use plastic or thin foil duct.
• Failure to follow these instructions can
result in death or fire.
• Clean old ducts before installing this dryer
!
■
ALTERNATE EXHAUST DIRECTIONS
1.
Remove screw and exhaust duct.
2-1.
Detach and remove the knockout that
matches the desired venting direction
(Right side not available on Gas Dryers)
,
,
the order of work.
2-2.
Reconnect the duct to the blower
housing and attach the duct to the
base.(Duct is a SVC part)
3-1.
Pre-assemble 4" elbow with 4" duct.
Wrap duct tape around joint.
3-2.
Insert elbow duct assembly first through the
side opening and connect the elbow to the
internal duct.
STEP 3
Connecting the Exhaust
and Venting System.
Vent end will face to the outside home and
improper taping and unstable installation of vent
will cause undesirable drying performance.
Note