22
INSTALLATION INSTRUCTIONS
Connecting Electric Dryers (cont.)
USA only
WARNINg
•
Connect the power cord to the terminal block.
Connect each power cord wire to the terminal block
screw that has the same colored wire. For example,
connect the black power cord wire to the terminal
block screw with the black wire. Failure to follow
these instructions may result in a short, overload,
fire or death.
•
Grounding through the neutral conductor is
prohibited for: (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and
(4) areas where local codes prohibit grounding
through the neutral conductor.
four-wire connection for electric dryers:
power cord
• A 4-wire connection is required for all mobile and
manufactured home installations, as well as all new
construction after January 1, 1996.
• A UL-listed strain relief is required.
1. Remove the terminal block access cover on the upper
back of the dryer. Install a UL-listed strain relief into
the power cord through-hole; then thread a UL-listed,
30 A / 240 V~, 4-wire, #10 AWG-minimum copper
conductor power cord through the strain relief.
•
Use a 30 A / 240 Vca UL-listed power cord with #10
AWG-minimum copper
conductor and closed loop or
forked terminals with upturned ends.
2. Pass the dryer’s ground wire from behind the green
ground screw to the center screw of the terminal
block. Attach the two hot leads of the power cord
to the outer terminal block screws. Attach the white
neutral wire to the center terminal block screw. Attach
the power cord ground wire to the green ground
screw.
TIGHTEN ALL SCREWS SECURELY
. Reinstall
the terminal block access cover.
Hot
(Black)
Power Cord
Ground Wire
Ground
Screw
White Wire
moved from
Ground Screw
Neutral
(White)
Hot
(Red)
UL-Listed
Strain Relief
UL-Listed
4-Wire Power
Cord
Terminal
Block