background image

3

1  Safety

1.1  Symbols

Caution, risk of electric shock

'RQRWSODFHRULQVWDOOQHDUÀDPPDEOHRUH[SORVLYHPDWHULDOV

Install the product out of reach of children

Read the instruction manual, in its entirety, before starting installation 
and operation

Heavy weight may cause serious back injuries

Do not dispose of the product with household waste

Recyclable

Disconnect the equipment before carrying out maintenance or repair

Observe precautions for handling electrostatic-sensitive devices

Protective Class 1

Caution, risk of electric shock, energy storage timed discharge.

1.2  Safety Instructions

For safety reasons, installers are responsible for familiarizing themselves with the contents of 
this document and all warnings before performing installation and servicing.

1.2.1  General Safety Precautions

Over-voltages or wrong wiring can damage the battery pack and cause combustion which can 
be extremely dangerous.

$Q\W\SHRISURGXFWEUHDNGRZQPD\OHDGWRDOHDNDJHRIHOHFWURO\WHVRUÀDPPDEOHJDV
$YRLGLQVWDOOLQJWKHEDWWHU\SDFNZKHUHÀDPPDEOHPDWHULDOVDUHVWRUHG'RQRWLQVWDOOLQSODFHV

where explosive gas or chemicals are present.
During installation of the battery, the utility grid and solar input must be disconnected from the 

%DWWHU\3DFNZLULQJ:LULQJPXVWEHFDUULHGRXWE\TXDOL¿HGSHUVRQQHO
%DWWHU\SDFNVKRXOGRQO\EHVHUYLFHGE\TXDOL¿HGSHUVRQQHO

The electronics inside the battery pack are vulnerable to electrostatic discharge.
Be sure to be grounded before handling the battery pack.
Read the label with Warning Symbols and Precautions, which are visible under the Battery 
Cover (see Section 

1.3 Warning Label

).

1.2.2  Battery Handling Guide

‡ 'RQRWH[SRVHWKHEDWWHU\WRDQRSHQÀDPH

‡ 'RQRWSODFHWKHSURGXFWQHDUWRKLJKO\ÀDPPDEOHPDWHULDOV

‡

Do not expose or place near water sources such as downspouts or sprinklers.

‡

Do not store or install the product in direct sunlight.

‡

Do not install the product in an airtight enclosure or in an area without ventilation.

‡

Do not install the product in living area of dwelling units or in sleeping units other 
than within utility closets and storage or utility spaces.

‡

Store in a cool and dry place. (Do not store in greenhouses or storage areas for 

KD\VWUDZFKD൵DQLPDOIHHGIHUWLOL]HUYHJHWDEOHVRUIUXLWSURGXFWV

‡ 6WRUHWKHSURGXFWRQDÀDWOHYHOVXUIDFH

‡

Store the product out of reach of children and animals.

‡

Store the product in clean environment, free of dust, dirt and debris.

‡ 'RQRWGLVFRQQHFWGLVDVVHPEOHRUUHSDLUWKHSURGXFWXQTXDOL¿HGSHUVRQQHO2QO\

TXDOL¿HGSHUVRQDODUHWRKDQGOHLQVWDOODQGVHUYLFHWKH3URGXFW

‡

Do not damage the Product by dropping, deforming, impacting, cutting or 

SHQHWUDWLQJZLWKDVKDUSREMHFW'RLQJVRPD\FDXVHD¿UHRUOHDNDJHRI

electrolytes.

‡

Do not touch the product if liquid spills on it. There is a risk of electric shock. 
Handle the battery wearing insulated gloves.

‡ 'RQRWVWHSRQWKHSURGXFWRUWKHSURGXFWཚVSDFNDJLQJVLQFHWKHSURGXFWPD\EH

damaged.

‡ 'RQRWSODFHDQ\IRUHLJQREMHFWVRQWRSRIWKH%DWWHU\3DFNDQGRQWKHFRROLQJ¿Q

‡

Do not put the battery pack upside down on the ground.

‡

Do not connect the power cables at terminal the block in the opposite direction.

‡

Do not charge or discharge a damaged battery.

‡

If the Product is installed in a garage or carport, ensure there is adequate clearance 
from vehicles.

‡ 7KHEDWWHU\SDFNKDVEHHQFHUWL¿HG,3DQGFDQEHLQVWDOOHGLQGRRUVDVZHOO

as outdoors. However, if installed outdoors, do not allow the battery pack to be 
exposed to direct sunlight or water sources, as they may cause:

-  Power limitation phenomena in the battery (with a resulting decrease in energy 

production by the system).

-  Premature wear of the electrical/electromechanical and mechanical components.
-  Reduction in performance, performance warranty and possible damage of the battery

‡

Only use the product with a LGES-authorized inverter.
For a list of compatible inverters, visit the LG ESS Battery Website by the URL 
below and check the ‘Home Battery’ > ‘Product Info’ menu.

https://www.lgessbattery.com/us (in case of North America) 
https://www.lgessbattery.com/au (in case of Australia) 
https://www.lgessbattery.com/eu (in case of all EU-countries in general)
https://www.lgessbattery.com/de (in case of Germany)
https://www.lgessbattery.com/it (in case of Italy)
https://www.lgessbattery.com/es (in case of Spain)

‡

Do not connect any AC conductors or photovoltaic conductors directly to the 
battery pack. These are only to be connected to the inverter.

1.2.3  Response to Emergency Situations

The Product includes internal fault mechanisms designed to prevent failures and subsequent 
risk hazards. However, LG Energy Solution cannot guarantee safety performance of the 
Product is ever exposed to abuse, damage or negligence.

‡

If a user happens to be exposed to the internal materials of the battery cell due to 
damage on the outer casing, the following actions are recommended. 

In case of inhalation: Leave the contaminated area immediately and seek medical 
attention.

In case of contact with eyes: Rinse eyes with running water for 15 minutes and 
seek medical attention.

In case of contact with skin: Wash the contacted area with soap thoroughly and 
seek medical attention.

In case of ingestion: Induce vomiting and seek medical attention.

,ID¿UHEUHDNVRXWDWWKHORFDWLRQZKHUHWKHEDWWHU\SDFNLVLQVWDOOHGSHUIRUPWKHIROORZLQJ

countermeasures.

‡

8WLOL]H¿UHH[WLQJXLVKLQJPHGLD

A respirator is not required during normal operation.

8VHDQ)0RU&2H[WLQJXLVKHUIRUEDWWHU\¿UHV
8VHDQ$%&¿UHH[WLQJXLVKHULIWKH¿UHLVQRWIURPWKHEDWWHU\DQGKDVQRW\HWVSUHDGWRLW

‡

)ROORZSURSHU¿UH¿JKWLQJLQVWUXFWLRQV

1. 

,ID¿UHRFFXUVZKHQFKDUJLQJEDWWHULHVSURYLGHGLWLVVDIHWRGRVRGLVFRQQHFW
WKHEDWWHU\SDFNFLUFXLWEUHDNHUWRVKXWR൵WKHSRZHUFKDUJH

2. 

,IWKHEDWWHU\SDFNLVQRWRQ¿UH\HWH[WLQJXLVKWKH¿UHEHIRUHWKHEDWWHU\SDFN
FDWFKHV¿UHSUHIHUDEO\ZLWKZDWHU

3. 

,IWKHEDWWHU\SDFNLVRQ¿UHGRQRWWU\WRH[WLQJXLVKLWDQGHYDFXDWHSHRSOH

from the premises immediately.

WARNING

There may be a possible explosion when batteries are heated above 150°C. When a 
battery pack is burning, it will leak poisonous gases. Do not approach it.

‡

(൵HFWLYHZD\VWRGHDOZLWKDFFLGHQWV

2QODQG3ODFHWKHGDPDJHGEDWWHU\LQWRDVHJUHJDWHGSODFHDQGFDOO\RXUORFDO¿UH

department or service engineer. 

In water:  Stay out of the water and do not touch anything if any part of the battery, inverter, 

or wiring is submerged. 

Do not use the submerged battery again. Contact your service engineer for assistance.

Summary of Contents for EH153064P8S1

Page 1: ...in following LG Energy Solution s product installation manual Warranty claims are invalid if damage is caused by human error in a manner inconsistent with the installation manual s instructions Version 1 02 Scan QR code to view Installation Video Guide Scan QR code to view Installation Manual PDF File ...

Page 2: ...tion 3 1 5 Clearance 3 1 6 Tools Safety Gear Required 3 1 7 Appearance and Dimensions 3 1 8 System Clearance 3 1 9 Installing the Battery Pack 3 2 Installation process for Remote Monitoring Device RMD 3 2 1 Prepare for installation using RMD 3 2 2 Installation via RMD 3 3 Cable Connections DEOH RQ JXUDWLRQ 3 3 2 Guide for cable connection and setting the DIP switch 3 3 3 Spring Terminal Blocks 4 C...

Page 3: ...l the block in the opposite direction Do not charge or discharge a damaged battery If the Product is installed in a garage or carport ensure there is adequate clearance from vehicles 7KH EDWWHU SDFN KDV EHHQ FHUWL HG 3 DQG FDQ EH LQVWDOOHG LQGRRUV DV ZHOO as outdoors However if installed outdoors do not allow the battery pack to be exposed to direct sunlight or water sources as they may cause Powe...

Page 4: ...vice Center or by D SHUVRQ ZKR LV VSHFLDOO DXWKRUL HG VHSDUDWHO IURP WKH LQVWDOODWLRQ TXDOL FDWLRQ 2 Product Introduction 2 1 Technical Data 2 1 1 Dimensions and Weight RESU10H Prime Part Number EH153064P8S1 Width 504 mm 19 8 Height 817 mm 32 2 Depth 295 mm 11 6 Weight 1 111 kg 244 lbs 1 Battery pack weights may vary slightly 2 1 2 Performance Electrical Characteristics Usable Energy 1 9 6 kWh Bat...

Page 5: ...ker shall inspect arc rated apparel before every use Work clothing RU DUF ÀDVK VXLWV WKDW DUH FRQWDPLQDWHG RU GDPDJHG WR WKH H WHQW LPSDLULQJ the protective qualities shall not be used Protective items that become FRQWDPLQDWHG ZLWK JUHDVH RLO ÀDPPDEOH OLTXLGV RU FRPEXVWLEOH PDWHULDOV shall not be used The garment manufacturer s instructions for care and maintenance of arc rated apparel shall be fo...

Page 6: ...l people may be required for moving equipment 3 1 4 Installation Location Requirements 7KHUH PXVW EH QR KLJKO ÀDPPDEOH RU H SORVLYH PDWHULDOV QHDUE The ambient temperature should be within the range of 4 F to 122 F 20 C to 50 C The battery pack must be installed on level ground that can support its weight Product shall be installed indoors ex in a basement or a garage or outdoors under an eave and...

Page 7: ...ual of the inverter NOTE An external DC isolator may be installed within the clearance zone Minimum clearances may be greater according to local regulations Inverter Floor 500mm 20 300mm 12 300mm 12 500mm 20 300mm 12 300mm 12 Inverter Ceiling Floor Inverter 500mm 20 300mm 12 300mm 12 500mm 20 300mm 12 300mm 12 300mm 12 Inverter Ceiling Floor Standing type Wall Mounting type 3 1 9 Installing the Ba...

Page 8: ...wrap from connectors of Battery Control Unit and the warning label of Battery Modules Pla ce th e sp ac er In th e lin e HE RE Pla ce th e sp ac er In th e lin e HE RE Pla ce th e sp ac er In th e lin e HE RE Pla ce th e sp ac er In th e lin e HE RE Pla ce th e sp ac er In th e lin e HE RE Pla ce th e sp ac er In th e lin e HE RE Pla ce th e sp ac er In th e lin e HE RE Pla ce th e sp ac er In th ...

Page 9: ...r In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE ...

Page 10: ...g to regional regulations Insert the RMD ethernet cable through Hole 2 and connect the cable Then proceed to Section 3 2 Installation for Remote Monitoring HYLFH 50 Internal cable Hole 2 Communication cable Hole 1 Power cable 23 Assemble the adapter or cap according to regional regulations Then insert the power and communication cables through the holes from outside of the pack Arrange the interna...

Page 11: ...ach Battery Module should face each other KHFN WKH ODEHO WR FRQ UP WKH Battery pack is of A Label is attached on the left side of Battery Module Module Support BRKT 6 Assemble Module Support BRKTs using 6 bolts each Tighten the M6 Flange Bolts x12 with a torque of 5N m Pl ac e th e sp ac er In th e lin e H ER E Pl ac e th e sp ac er In th e lin e H ER E Pl ac e th e sp ac er In th e lin e H ER E P...

Page 12: ...lockwise If you experience any problems at this stage go to Section 5 Troubleshooting Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac er In th e lin e HE RE Pl ac e th e sp ac e...

Page 13: ... In th e lin e HE RE Handle Front Cover 19 Open the front cover Hold the handle and turn it counterclockwise M5 PH Bolt 6ea Front Protection Cover 20 Loosen 6 bolts and remove the Front Protection Cover Be careful not to drop the bolts into the pack at this stage Connector for Ethernet cable Hole 2 Hole 1 21 Assemble the adapter or cap according to regional regulations Insert the RMD ethernet cabl...

Page 14: ...ign In button ဵ I RX GRQ W KDYH RXU DFFRXQW SOHDVH YLVLW 66 DWWHU ZHEVLWH DQG PDNH DQ DFFRXQW https www lgessbattery com us in case of North America https www lgessbattery com au in case of Australia https www lgessbattery com eu in case of all EU countries in general https www lgessbattery com de in case of Germany https www lgessbattery com it in case of Italy https www lgessbattery com es in ca...

Page 15: ... your authentication key at the e mail address you provided 7 Enter your authentication key within 3 minutes to verify your account 8 OLFN WKH RQ UP EXWWRQ 0 9 Select the Owner option 10 Enter your ID and Password 11 Click the Sign In button QVWDOODWLRQ YLD 50 OLFN WKH OLQN RQ WKH 5 68 0RQLWRU ZHEVLWH WR GRZQORDG WKH 3 OH RI WKH µ5 68 QVWDOOHU App NOTE Depending on the device RESU Installer App ma...

Page 16: ... Next button 3 2 2 5 QR Code Scan The QR code scanning method is as follows Select Prime Fixed at 2 FLEX Select from 2 to 4 S N of consecutive QR codes are automatically displayed Maximun 5 When the QR code registration is complete click the Next button If the scanned serial number matches the actual serial number it will proceed to the next section There are three 3 QR codes Battery Control Unit ...

Page 17: ...WLRQ DQG DWWHU 6WDWXV KHFN IoT Hub Connection String Enter the unique string provided to you in order to access the Azure IoT Hub cloud server The string format is as follows HostName emashub azure devices net DeviceId XXXX SharedAccessKey OOOO For more information on how to obtain strings refer to Section 3 2 1 2 Obtaining IoT Hub String Server Connection Check Check the server connection Battery...

Page 18: ...itch Communication Termination resistor all downwards for single pack ဵ KHQ RX LQVWDOO WZR SDFNV UHIHU to the appendix about setting for communication termination resistor 3 Section C DIP switch for setting primary secondary packs Raise all DIP switch upward when you want to use as a primary pack And also when you want to use as a secondary pack lower the switch on the right side only when viewed ...

Page 19: ...the front cover 5 Troubleshooting 7URXEOHVKRRWLQJ 2YHUYLHZ Check the LED indicators on the front to determine the state of the battery pack A fault state is triggered when certain conditions like voltage or temperature are beyond design limitations The battery pack s BMS periodically reports its operating state to the inverter When the battery pack falls outside of prescribed limits it enters a fa...

Page 20: ...ircuit breaker 6 Contact LG Energy Solution regional service contact point LED Status Action Power on Charging Discharging If the LED fault indicator is ON 1 Check if the inverter recognizes the battery Refer to the inverter s troubleshooting guide for battery setup instructions 2 I WKH LQYHUWHU LV FRQQHFWHG WR WKH LQWHUQHW FROOHFW WKH ORJ OHV IURP WKH LQYHUWHU company 2 1 Send the fault ID to LG ...

Page 21: ...c e th e sp ac er In th e lin e HE RE Battery Control Unit Spacer 11 After that place the second spacer on top of the Battery Modules Pla ce the spa cer In the lin e HE RE Pla ce the spa cer In the lin e HE RE Pla ce the spa cer In the lin e HE RE Pla ce the spa cer In the lin e HE RE Pla ce the spa cer In the lin e HE RE Pla ce the spa cer In the lin e HE RE Pla ce the spa cer In the lin e HE RE ...

Page 22: ...ave Inverter Primary Pack Terminating resister ON 1 Case 1 When installing one battery pack Turn ON the DIP switch for communication termination resistor It is ON when switches are lowered Inverter already have already have Inverter Primary Pack Primary Pack Terminating resister ON Terminating resister ON 2 Case 2 1 When installing two battery packs and inverter has two communication ports separat...

Page 23: ...r cable is connected by combiner Box Positive and negative line should be connected same polarity line by combiner box Joint connection is in the combiner box If installer connected reverse polarity position of the power line the battery system is not normally operated Primary Pack Inverter Combine box Secondary Pack GND GND Primary Pack Secondary Pack Combine box Inverter GND GND 7 2 RMD Applicat...

Page 24: ...nnect the cable between Top cover assy and BMA Retrieve pack if issue occurs repeatedly BMS Internal Fault2 DiagResultHwFault2 0x0004 Try restarting the battery Retrieve pack if issue occurs repeatedly DiagResultHwFault2 0x1000 DiagResultFault2 0x10000 DiagResultHwFault2 0x0001 DiagResultHwFault2 0x0008 DiagResultHwFault2 0x0200 DiagResultHwFault2 0x0100 DiagResultHwFault2 0x0040 DiagResultHwFault...

Page 25: ...HFWHG correctly click the Send button 6 If you check the success message in the upper right corner the update was successful QVWDOODWLRQ YLD 50 IRU ZHE XVHU 7 2 3 1 User Agreement Visit https resumonitor lgensol com and Sign in 1 2 3 4 5 6 7 8 OLFN QVWDOODWLRQ ĺ 8VHU JUHHPHQW DQG VHDUFK WKH SURGXFW ZKLFK RX ZLOO LQVWDOO Select your region Non EU EU Get the agreement of privacy policy for the custo...

Page 26: ...gister to go to the home screen The default password is set to 123456 and can be changed in the Web UI RQ J VHWWLQJ 1 Server Use Decide whether to use connect to the cloud server 2 Inverter Type N A 3 BMA Number Select number of Modules Select 2 4 Communication Type N A 5 Country Select country 6 Time Zone Hour Option to display 1hour in UTC 7 Time Zone Minute Option to display 15 minute unit 8 Po...

Page 27: ... AP to access from the SSID combo box enter the password and click the Connect button Manual input is possible 4 If the connection to the AP is successful a pop up window informs whether the connection was successful as follows 7 2 3 6 Check the Installation Status QWHU WKH 0RQLWRULQJ ĺ 6HUYHU 7DE KHFN WKH 6WDWXV YDOXHV DUH µ2 KHWKHU WKH WKHUQHW connection or Wi Fi connection OK depends on the ser...

Page 28: ... 2021 LG Energy Solution ESS Battery Division PARC1 108 Yeoui daero Yeongdeungpo gu Seoul Republic of Korea 07335 https www lghomebattery com http www lgensol com Keep this manual for later use ...