- 14 -
220
IBM
Compatible PC
PARALLEL PORT
Power inlet (required)
Power LED
ST Switch
Power Select Switch
(110V/220V)
Control Line
Not used
RS232C
PARALLEL
V-SYNC
POW
ER
ST
VGS
MONITOR
E
E
V-Sync On/Off Switch
(Switch must be ON.)
F
F
A
A
B
B
C
C
15
10
5
5
6
9
1
1
1
14
13
25
6
5V
5V
5V
4.7K
4.7K
4.7K
74LS06
74LS06
OFF
ON
OFF
ON
11
Video Signal
Generator
Figure 1. Cable Connection
SERVICE OSD
1) Turn off the power switch at the right side of the display.
2) Wait for about 5 seconds and press MENU, POWER switch for 1 second interval.
3) The SVC OSD menu contains additional menus that the User OSD menu as described below.
a) NVRAM INITIAL : To make shipping state.
b) ADC CALIB RGB : RGB input calibration of ADC
c) ADC CALIB COMP : Component input calibration of ADC
d) AGING MODE : On / Off
e) ELAPSED TIME CLEAR : Erase using time.
f) WHITE BALANCE : Adjustment white balance manually.(Only HDMI(video), Component)
Summary of Contents for Flatron L245WP
Page 8: ...TIMING CHART 8 VIDEO SYNC F E C A B D PC INPUT ...
Page 22: ...EXPLODED VIEW 22 010 120 020 080 070 090 140 100 110 030 040 060 050 130 ...
Page 31: ...SCHEMATIC DIAGRAM 31 1 CONNECTORS JACKS ...
Page 32: ... 32 2 SCALER ...
Page 33: ... 33 3 COMP INPUT A D CONVERTER ...
Page 34: ... 34 4 POWER CONNECTION ...
Page 35: ... 35 5 USB ...
Page 36: ... 36 6 HDMI ...
Page 37: ... 37 7 CONTROL ...