63
Track Servo is unstable
Is TE signal
output normal in Focusing
ON and Tracking OFF?
(IC200 pin 121)
YES
•
Check the PICK UP FFC.
•
Replace the PICK UP.
Replace the IC200.
•
Check the connection between
IC100(Pin205) and IC200 (Pin
121)
NO
Is TE signal
input normal in Focusing
ON and Tracking OFF?
(IC100 pin 205)
NO
Replace the IC100.
Check the Drive IC(IC300) and
P/U referring to “Focus Actuator
operating is abnormal”.
Is there TRO
signal output in Tracking ON?
(IC100 pin13)
NO
Is PICK UP
(E, F, G, H) output normal?
(CN101 pin 3, 6, 7, 10)
YES
YES
YES
NO