64
A. Start
1. Install GCE-8480B -> PC Power ON -> Execute Windows.
2. Execute
GGOOM5.exe
on Windows (GGOOM5.exe & GGOOM5.cfg should be on the same Directory).
3. If you use GCE-8480B, “GGOOM5(Ver x.xx)” will be displayed on the Window Frame.
4. Select
I/F Setup
on the menu bar.
5. Select
ATAPI I/F
and then Click
OK
.
6. Select
Target Select
on the menu bar.
7. Select
Number of Host(#0 or #1)
appropriately, then
“GCE-8480B”
displays on Target Device.
8. Select “
GCE-8480B
” on Target Device, and then Click
OK.
B. Check ALPC Parameters
1. Select
VIEW
on the menu bar.
2. Click
Addition Func.
on VIEW window -> New frame will be displayed.
3. Click
ALPC Para
tab.
[ALPC Parameters]
1) CD-R READ Reference DAC : 60 ~185
2) CD-RW READ Reference DAC : 60 ~185
3) VWDC1 - VWDC1 Offset : 225 ~ 296
4) VWDC1 Offset : 30 ~ 175
5) VWDC2 - VWDC2 Offset : 522 ~787
6) VWDC2 Offset : -55 ~ 75
4.
Close
Calibration window.
• How to use Test Tool (GGOOM5)
[I/F Setup Menu]
[Target Select window]
[ALPC Parameters Menu]
[Additional Function Menu]