33
MICOM Function and Description of Circuit
3. Sensor Resistance Characteristics Table
➲
Allowance of sensor resistance is 5%.
➲
Measure resistance value of sensor after leaving it for more than 3 minutes (delay is required due
to sensing speed).
➲
Always use a digital tester! Analog testers have too great a margin of error.
➲
For the left compartment sensor, measure both ends of Nº. 1 and Nº. 2 after separating CON2
from the PCB Assembly. For the right compartment sensor, measure both ends of Nº. 1 and Nº. 2
of CON3. For the outside (ambient) sensor, measure both ends of Nº. 1 and Nº. 2 of CON5.
Measuring Temperature(°C)
Left Sensor, Right Sensor
-20° C
77 K
Ω
-15° C
60 K
Ω
-10° C
47.3 K
Ω
-5° C
38.4 K
Ω
0° C
30 K
Ω
+5° C
24.1 K
Ω
+10° C
19.5 K
Ω
+15° C
15.9 K
Ω
+20° C
13 K
Ω
+25° C
11 K
Ω
+30° C
8.9 K
Ω
+40° C
6.2 K
Ω
+50° C
4.3 K
Ω