Earth Grounding
•
The solar modules from LG Electronics
meet the conditions of Safety Class II.
Therefore grounding is not mandatory.
However grounding is recommended.
Also equipotential bonding must be
realized. The national directives must be
respected.
•
Specific information on the solar module
dimensions and location of grounding
holes is provided in the related data sheet.
ELECTRICAL INSTALLATION
•
One M4 stainless steel bolt, two flat
washers, one star washer, one cup washer,
one spring washer, one nut, and
12 AWG Cu wires are recommended per
solar module.
•
There is an earth hole in the center of the
module frame. Using this hole, an earth
conductor and the solar module frame
may be recommended to connect and
earth as the below drawing.
Moduleframe
Bolt
Flat washer
Star washer
Cup washer
Grounding wire
Flat washer
Spring washer
Nut