MECHANICAL INSTALLATION
LGxxxS1C(W,K)-G3/-A3/-B3, LGxxxN1C(W,K)-G3/-A3/-B3
Mounting T
ype
Clamping T
ype
(L
ong Side
)
Clamping T
ype
(Short Side
)
Use four mounting holes on two opposite sides.
Use four clamps on the long frame.
2400 Pa: A = 100 mm, B = 450 mm
5400 Pa: A = 270 mm, B = 230 mm
Use four clamps on the short frame and
two clamps at the center of the long frame.
Use four clamps on the short frame.
This installation is allowed in the following cases:
1. Slope roof: If module is installed parallel to the
rooftop
2. Flat roof: If installed with an additional stand such
as wind shield or deflector
This method is not tested by IEC/UL.
Center ± 100 mm
Center ± 100 mm
A
A
Clamping Range:
from module edge to
270 mm
Clamping Range
B
Clamping Range:
from module edge to
120 mm