13
ENGLISH
INSTALLATION INSTRUCTIONS
To check ignition of the Bake burner, follow the steps
below:
1) Remove all packing from inside the oven cavity.
2) Press "Bake" (350 will be shown in the display).
3) Press Start.
It may take between 30 and 90 seconds for the burner
to start heating.
To check ignition of the Broil burner, follow the steps
below:
1) Press "Broil" ("Hi" will be shown in the display).
2) Make sure the door is closed.
3) Press Start.
It may take between 30 and 90 seconds for the burner
to start heating.
NOTE: Do not try and light either the bake or broil
burners during a power outage. The range has an
electrical ignition system and can not be used
without power.
8. CHECK OPERATION OF BAKE/BROIL BURNERS
The range comes from the factory with air shutters adjusted for proper air flow for natural gas.
If converted to LP, follow the instructions provided in the conversion kit to properly adjust the air shutters.
LP conversion must be performed by a qualified technician.
9. AIR SHUTTER ADJUSTMENT FOR BAKE AND BROIL
BURNERS.