3-2
COMPONENT ACCESS
1. Turn off the electrical supply and gas supply going to the range.
2. Pull the range away from the wall so that you can
access the rear panel.
3. Remove two wire covers by removing the screw.
4. Remove the 3 screws from the rear control cover
and remove the cover.
5. Remove the 4 screws from the safety valve cover
and remove the safety valve cover.
6. Remove the 17 screws from the rear back cover and remove rear back cover.
8. Remove the 2 screws of the eyebrow from the
controller sub assembly and remove the eyebrow.
9. Remove the 4 screws of controller sub assembly.
10. Pull the controller sub assembly and lift it up
from the supporters.
11. Remove the 3 screws of controller sub
assembly.
12. Replace the key pad assembly.
7. Remove the 12 screws of PCB assembly and separate
PCB assembly after unpluging the connectors.
REMOVING THE BACK, CONTROL COVER
REMOVING THE BACK, CONTROL COVER
AND KEY P
AND KEY P
AD ASSEMBL
AD ASSEMBL
Y
Y
WARNING
• DISCONNECT power supply cord
from the outlet before servicing.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
Control Cover
Wire cover
Back Cover
Safety Valve
Cover
8 connectors of PCB
5 spark ignitions
CAUTION
• Be careful when you work on the gas
range handling the sheet metal part.
- Sharp edge may be present and you can cut
yourself.
Eyebrow
Pull