4-2
Micro Switch
(normally open type)
Oven Sensor
Door switch
1. Refer to page 3-15, 3-16 for the servicing
procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
1. Refer to page 3-17 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
Normal: Approximately
1.09 k
Ω
± 10%
If not replace
Components
Test procedures
Results
NO
COM
Door latch
open
Door latch
Locked
Continuity
Infinite
NOTE:
After checking for the continuity of switch, make sure that they are
connected correctly
NOTE:
Oven sensor is so sensitive to temperature
Do test after cooling down sufficiently
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
1. Refer to page 3-8, 3-10 for the servicing
procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1)
Door open
Door closed
Continuity
Infinite