4) Insert a small, flat bladed screwdriver into the
valve shaft as shown in Fig. 1.
Turn the adjustment screw until the flame
reaches the desired size.
5) Replace the knob.
6) Test the flame stability.
Test 1
: Turn the knob from “HI” to “LOW”
quickly. If the flame goes out, increase the
flame size and test again.
Test 2
: With the burner on a “LOW” setting,
open and close the oven door quickly. If the
flame is extinguished by the air currents
created by the door movement, increase the
flame height and test again.
7) Repeat steps 1-5 for each surface burner.
10. CONVERSION STICKER
Upon completion of the conversion, fill out the
LP sticker located with the instructions. Once
complete, attach the sticker to the back of the
range near the regulator.
Place all orifice's that were removed for natural
gas back into the plastic bag along with the
instructions. Place the kit back into its original
location.
Follow conversion process with original orifices to
convert the appliance to the original gas.
NOTE:
The choke for the 17k top burner must be
removed when converting the range back to natural gas.
5-5
CONVERSION TO LP GAS
WARNING
• Turn off the electrical supply and
gas supply going to the range.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the
gas range handling the sheet metal
part.
- Sharp edge may be present and you can cut
yourself.
8. CHECK QUALITY OF THE FLAMES
The combustion quality of the burner flames
needs to be determined visually.
A. Yellow Flames:
Further Adjustment Required
B. Yellow tips on outer cones:
Normal for LP Gas
C. Soft Blue flames:
Normal for Natural Gas.
NOTE:
If burner flames look like A Further air
shutter adjustment is required. B or C is normal
burner flames, depending on the type of gas you
use. With LP gas, some yellow tipping on the outer
cones is normal.
9. ADJUST THE SURFACE BURNER LOW
FLAME(SIMMER) SETTING.
1) Light all surface burners.
2) Turn the knob on the burner being adjusted to
“LO”
3) Remove knob.
Fig.1
Center adjustment screw
CONVERSION IS FINISHED
To convert to the original gas.