Instructions for the installer
The connection terminals are located at the rear of the appliance.
For electrical connections see following diagram. To access,
remove the rear cover.
For operation on 380-415V3N~:
use an
H05RR-F / H05RN-F / H05V2V2-F type five-core
cable (5 x 1.5 mm
2
).
For operation on 380-415V2N~:
use an
H05RR-F / H05RN-F / H05V2V2-F type five-core
cable (cavo di 4 x 2.5 mm
2
).
For operation on 220-240V~:
use an H05RR-F
/ H05RN-F / H05V2V2-F (cavo di 3 x 4 mm
2
).
The cable end to be connected to the appliance
must be provided with an ground wire (yellow-
green) at least 20 mm longer.
Complete wiring up to power supply with an appropriately rated
five-core plug (see data plate) or, in case of operation from a
220-
240V~
power supply, with a three-core plug. Make sure that plug
and wall socket are of the same type and are in conformity with
regulations in force. Make sure that the appliance is properly
earthed. Before powering, check that the power line is properly
earthed. Avoid using adapters or shunters.
The manufacturer declines all responsibility
for damage to
persons or things caused by non-observance of the above
prescriptions or by interference with any part of the appliance.
6