6. TROUBLESHOOTING
- 13 -
6-1 COMPRESSOR AND ELECTRIC COMPONENTS
1
2
3
4
5
2
5
5
3
5
1
4
3
YES
NO
YES
The range of resistance is between 1~50½ (ok)
Open or short
YES
YES
NO
NO
Power source.
No voltage.
(Rated voltage
±10%)?
Replace OLP.
Reconnect.
Refer to page 12.
Refer to page 12.
Did
compressor
start?
Compressor
is OK
Replace the
compressor
Check connection
condition.
OLP disconnected?
Advise customer that
power supply needs to be
checked by an electrician.
Replace
compressor.
Supply
voltage rating
with ±10%.
Applied voltage isn't
in acceptable range.
(115V ±10%)
Remove PTC-Starter
from compressor and
measure voltage
between terminal C of
compressor and
terminal 5 or 6 of PTC.
Check resistance
between M-C, S-C and
M-S in motor
compressor.
Check resistance of
two terminals in
PTC-Starter.
Check resistance of two
terminals in OLP.
Check the power supply
under load.
(Compressor attempting
to re-start after being off
for 5 minutes).
Check
resistance of
motor
compressor.
Check
resistance of
PTC-Starter.
Check OLP.
Check
starting state.
Summary of Contents for LFD21860ST
Page 12: ...5 CIRCUIT DIAGRAM 12 ...
Page 36: ...8 5 MAIN PWB ASSEMBLY AND PARTS LIST 8 5 1 Main PWB Assembly 36 ...
Page 37: ...8 5 2 Replacement Parts List 37 ...
Page 38: ...8 5 3 PWB Assembly Display And Parts List 38 ...
Page 39: ...8 6 PWB DIAGRAM 8 6 1 PWB Main Assembly 39 ...
Page 40: ... 40 ...