7-2-5 Function TEST
1. This is a compulsory operation for test, service, cleaning, etc. It is operated by pressing and holding the fill key for 3 seconds.
2. The test works only in the icemaking mode. It cannot be entered from the harvest or fill mode. (If there is an ERROR, it
can only be checked in the test mode.)
3.
Caution!
If the test is performed before water in the icemaker is frozen, the ejector will pass through the water. When the
fill mode begins (stage 4), unless the water supply has been shut off, added water will overflow into the ice bin. If the
control doesn’t operate normally in the test mode, check and repair as needed.
4. After water is supplied, the normal cycle is followed:
icemaking
→
harvest
→
fill
→
park position
.
5. Five seconds after stage 5 is completed, the icemaker returns to MICOM control. The time needed to supply water resets
to the pre-test setting.
7-3 DEFECT DIAGNOSIS FUNCTION
7-3-1 ERROR CODE on water supply control panel at Ice Maker
- 22 -
Summary of Contents for LFD21860ST
Page 12: ...5 CIRCUIT DIAGRAM 12 ...
Page 36: ...8 5 MAIN PWB ASSEMBLY AND PARTS LIST 8 5 1 Main PWB Assembly 36 ...
Page 37: ...8 5 2 Replacement Parts List 37 ...
Page 38: ...8 5 3 PWB Assembly Display And Parts List 38 ...
Page 39: ...8 6 PWB DIAGRAM 8 6 1 PWB Main Assembly 39 ...
Page 40: ... 40 ...