- 33 -
8-10 Icing Fan Error (Er IF)
No
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Open the Refrigerator door and Check the
air flow.
3
Check the Connector.
(Frozen caused the PCB short)
Result & SVC Action
Status
No windy
Windy
SVC Action
Go to the 3,4
Go to the 5
4
Check the Fan motor voltage.
Below 9 V
0 or 5 V
(1) ~ (2)
(1) ~ (3)
Change the PCB
Change the motor
Point
Result
SVC Action
<CON7>
(3) (2) (1)