- 35 -
8-12 Communication Error (Er CO)
No
1
2
Checking flow
Check the loose connection.
Check the Red to White/Red.
Result & SVC Action
Result
12 V
Other
SVC Action
Go to the 3
Check the Hinge
(loose connection)
Change the Main PCB
5
Check the White/Red to Orange.
6
Check the White/Red to White/Black.
<CON5>
<CON5>
<CON101>
3
Check the Orange to White/Red.
Result
0 or 5 V
Other
SVC Action
Change the Display PCB
Go to the 4
4
Check the White/Black to White/Red.
Result
0 or 5 V
Other
SVC Action
Change the Main PCB
Go to the 5
Result
0 or 5 V
Other
SVC Action
Change the Display PCB
Go to the 6
Result
0 or 5 V
Other
SVC Action
Change the Main PCB
Explain to customer
CON101
<Display>
<CON101>
CON101
<Display>
<CON101>
CON101
<Display>
Summary of Contents for LFX31915 Series
Page 20: ... 20 5 CIRCUIT DIAGRAM ...