- 41 -
9-6 Poor cooling in Fresh food section
No
1
Checking flow
Check the sensor resistance.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Check If cold air blows from air vent with
your hand.
The sensor is determined by
the temperature.
For example, 30
indicates 32°F.
Result & SVC Action
<CON7>
Temperature
23°F
°C
32°F
°C
41°F
°C
50°F
°C
59°F
°C
Result
38
30
24
19.5
16
Status
Windy
No windy
SVC Action
Go to the 4
Check the R Fan motor
Check the damper
(Go to the 6)
5
Check the air temperature.
Cold or not ?
Status
Cold
Not cold
SVC Action
Explain to customer
Check the Compressor
And sealed system