12
PRODUCT SPECIFICATIONS
Rated electrical characteristic except power rating within -0/+3 percent are within 5 percent of measured.
Values at Standard
Test Condition(STC) : Irradiance 1000W/m
2
, Cell temp. 25
℃
, 1.5AM
※
See more information
>>
http://www.staubli-alternative-energies.com
http://www.renhesolar.com
http://www.ukt-sz.com
Model
Cable Cross Section
Ø A (Cable outer diameter)
Rated current
MC4
4mm²
5.5 ~ 9.0mm
30A
12AWG
05-8
4mm²
5.4 ~ 7.2mm
20A
12AWG
PV-CO02
4mm²
4.0 ~ 7.0mm
20A
12AWG
Ø A
Ø A
◇
Female and male cable couplers
◇
Female cable coupler
Male cable coupler
Note) MC4 formal name : PV-KST4 / 6II-UR, PV-KBT4 / 6II-UR
should be selected according to the installation site conditions and local code.
“Max. No. of modules in series” is considering 125% of Voc. Actual number of connections
→ Plus (+) Connector : Male MC4 coupler (PV-KST4/6II-UR)
→ Negative (-) Connector : Female MC4 coupler (PV-KBT4/6II-UR)
Note) The Typical change in module efficiency at 200W/m in relation to 1000W/m is -3.0%
2
2
Electrical Properties
Mechanical Properties
Module
Series
Model Name
Pmax
at STC
Pmax
at
Bifi100
Pmax
at
Bifi200
Power
Tolerance
Voc at
STC
Isc at
STC
Vmpp
at STC
Impp at
STC
Max.
Series
Fuse
Rating
Max.
No. of
module
in series
Max.
System
Voltage
Connector Length Width Height Weight
W
%
V
A
V
A
A
V
mm
mm
mm
kg
40.6
10.83
33.9
10.35
40.8
10.93
34.0
10.44
41.0
11.03
34.3
10.51
41.2
11.13
34.5
10.60
41.4
11.23
34.7
10.68
41.5
11.33
34.9
10.75
41.7
11.43
35.2
10.83
18.5
18.5
18.5
18.5
18.5
18.5
18.5
MC4 / 05-8
/ PV-CO02
MC4 / 05-8
/ PV-CO02
MC4 / 05-8
/ PV-CO02
MC4 / 05-8
/ PV-CO02
MC4 / 05-8
/ PV-CO02
MC4 / 05-8
/ PV-CO02
MC4 / 05-8
/ PV-CO02
0~3%
19
20
1000
1042
40
0~3%
19
20
1000
1042
40
0~3%
19
20
1000
1042
40
0~3%
19
20
1000
1042
40
0~3%
19
20
1000
1042
40
LG360N1K-N6
360
1768
LG365N1K-N6
365
1768
LG370N1K-N6
370
1768
LG375N1K-N6
375
1768
LG380N1K-N6
380
1768
LGXXXN1K-N6
LG350N1K-N6
350
0~3%
19
20
1000
1768 1042
40
LG355N1K-N6
355
0~3%
19
20
1000
1768 1042
40
W
363
368
373
378
383
353
358
W
366
372
377
382
387
356
361
N-TYPE
Note) Max. Bifaciality Coefficient of Power : 0.09
Max. Bifaciality Coefficient of Current : 0.10
Max. Bifaciality Coefficient of Voltage : 0.91
For information about the electrical ratings for both front and back surfaces (Bifaciality Coefficient) and the expected contribution from ground reflected irradiance
along with ground cover and installation height above ground that reflected irradianc
e, please refer to the sales talk material and datasheet.
Note)