background image

BEFORE & AFTER INSTALLATION

Before Installation

5

Please carefully read this manual before installation.

Solar module installation and maintenance must be 

performed by qualified and authorized installer.

All installation instructions should be read and 

understood before performing any installation.

Do not touch the solar module with bare hands.

It may result in a burn or injury.

Do not disassemble the solar module.

After installation or repair, check that the solar module

are operating properly.

In the event that the currently used solar module or p

arts have been replaced the newly replaced module a

nd parts must have the same model name and parts a

s the previously installed solar module.

In the case of a different model name replacement,

After Installation

Plug in the connector tightly and ensure that the wiring

properly works.

electrical characteristic model within 80% of the maximum

Conduct periodic inspection of the panels for damage

to front glass, back sheet, frame, junction box, or

external electrical connections.

Check electrical connections for loose connections

and corrosion.

PV panels can operate effectively without ever being washed,

although removal of dirt from the front glass can increase

output.

Water, ethanol or a conventional glass cleanser with a

micro-fiber cloth can be used for regular washing or ri

nsing of the front glass to remove dust, dirt or other de

posits.

Do not use ground water containing calcium carbonate 

components when cleaning glass.

Aggressive and abrasive cleansers or chemicals such

as alkali chemicals including ammonia based solution

should not be used on cleaning the module.

Always keep the back surface of the panel free from a

ny foreign objects or structural elements which could c

ome into contact with the panel, especially when the p

anel is under mechanical load.

Deposits of foreign material on the frame surface can

be cleaned by using a wet sponge or cloth and dried i

n air or by using a clean chamois.

Perform the wiring work by connecting the connector

and wires to the stand away from the roof or ground.

Do not use any kind of oil or lubricant on the module's

any parts, It can defect the PV Module.

voltage of the system.

Do not let anyone approach the solar module who has lit

tle knowledge of solar modules or on the measures to ta

ke when solar modules are damaged in order to avoid th

e risk of injury or electrical shock.

Secure all necessary permits and licenses to install

the solar modules.

Do not locate the solar module horizontally, as this may

cause dirt or white efflorescence(glass deformation).

Panels are not intended for use indoors or on moving

vehicles of any kind.

Industry standard rated specifications are made at

conditions of 1000W/m

2

irradiance and 25

°C (77°F)

solar cell temperature. Colder temperatures may su

bstantially increase voltage and power.

Keep the solar module and system away from children

at all times.

Keep the module packed in the carton until the time of

installation.

Keep flammable gasses away from the installation

site.

Do not work alone. Please work as part of a team of

two or more people.

Safety harness use is strongly recommended for

installation.

Be careful not to damage the cable when using a tool

such as a knife to remove the cable tie that fixes the j

unction box cable.

Partial shadowing may substantially reduce panel and

system output and may be the reason for the damage

of solar module.

Care must be taken to avoid low tilt angles which may

cause dirt to buildup on the glass against the frame ed

ge.

Dirt build-up on the surface of the panel may cause

active solar cells to be shaded and electrical perfor

mance to be impaired.

it is possible to replace an equivalent or higher

Summary of Contents for LG N3C(W)-V6 Series

Page 1: ...Please read this manual carefully before operating your set and retain it for future reference N TYPE MODELS LGXXXN3C W V6 LGXXXN3K V6 www lgsolarusa com Installation manual PV Solar MODULE ...

Page 2: ...tions 06 Diodes 06 Series Connection 06 Parallel Connection 07 General Wiring 07 Earth Grounding 07 MECHANICAL INSTALLATION 08 Module Mounting 08 Site Consideration 08 Mounting Methods 08 DISCLAIMER OF LIABILITY DISPOSAL 10 TRANSPORTING AND STORAGE 10 REVISIONS TABLE 10 PRODUCT SPECIFICATIONS 11 Electrical Mechanical Properties 11 Dimensions of Modules 13 ...

Page 3: ...sult in accide nt or death Damaged modules must be treat ed with safety protection equipme nt Failure to comply may result i n serious bodily injury or death No electrical parts like cables are located after installation between laminate and mounting structure Do Not reconnect or repair junct ion box cable It may occur spar k or electric shock Do not bending junction box s ca ble While under stres...

Page 4: ...e Failure to comply may result in damage of the product If the installing modules on curved surface e g arch ty pe as shown in the below picture do not forcefully mo dify the module in the installation when connecting it wi th the structure Only install the module in the place wh ere the structure for the panels has been properly set u p An improper structure may cause deformation of the panels Pa...

Page 5: ...contact with the panel especially when the p anel is under mechanical load Deposits of foreign material on the frame surface can be cleaned by using a wet sponge or cloth and dried i n air or by using a clean chamois Perform the wiring work by connecting the connector and wires to the stand away from the roof or ground Do not use any kind of oil or lubricant on the module s any parts It can defect...

Page 6: ...n the guidelines on the product specification s heet Please use only the same type of modules in a combined source circuit Do not disconnect the module under when it is op erating Shock hazard may occur near the solar m odules connection means When the module installing in series or in parallel e g using for extension cables etc the connector of each module should be the same products mated with i...

Page 7: ... recommends that all wiring be double insulated with a minimum rating of 90 C 194 F All Wiring should use a flexible copper Cu conductor The minimum size should be determined by the applicable codes LG Electronics recommends a size no smaller than 12AWG 7 Earth Grounding All work must be conducted in conformance with all Federal State and local codes and standards Grounding works should be perform...

Page 8: ...lls of living places Module Strength Basic Load CSA UL61730 Ym is a safety factor of 1 5 Detail of mounting distance is below This mounting method is by using frame bolt holes The mounting rails must run perpendicularly to the module long side Mounting Methods General Information Select the appropriate orientation to maximize sunlight exposure The module generates maximum output power when it face...

Page 9: ...lipping snow We recommend to use corrosion resistant material according to standard CSA UL61730 for these supporting part A snow guard should be installed in accordance with the manufacturer s instructions Solar module Supporting part Roof Mounting by using frame bolts holes Secure the solar module to the structure by using the factory mounting holes Four M8 stainless steel bolts four nuts four sp...

Page 10: ...demands losses or damages on my account caused or alleged to be caused in whole or in part by the negligence of the LG its affiliated companies successors or assigns its administrators directors officers volunteer and employees Disposal Please contact your local disposal center or Dealer Distributor TRANSPORTINGAND STORAGE Do not loosen the banding when the module is transported by truck ship and ...

Page 11: ...2AWG Note Max Bifaciality Coefficient of Power N3C W V6 0 04 N3K V6 0 06 Max Bifaciality Coefficient of Current N3C W V6 0 05 N3K V6 0 07 Max Bifaciality Coefficient of Voltage N3C W V6 0 88 N3K V6 0 88 11 Note For information about the electrical ratings for both front and back surfaces Bifaciality Coefficient and the expected contribution from ground reflected irradiance along with ground cover ...

Page 12: ...Dimensions of Modules Unit mm in LGXXXN3C W V6 LGXXXN3K V6 Frame Cross section Long Frame Short Frame 12 ...

Page 13: ... lg solar lge com http www lgsolarusa com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and i ntellectual properties of LG Electronics Inc are protected by international copyright laws ...

Page 14: ...228 890 990 ...

Page 15: ...Note All mechanical installation methods and bolting method in this appendix were not tested by CSA or 3rd party It is evaluated by LG internal test ...

Page 16: ......

Page 17: ......

Page 18: ......

Reviews: