background image

Mechanical Installation 

Module Mounting 

• The  LG  Electronics‟  (LGE)  Limited Warranty  for  solar 
modules  is  contingent  upon  modules  being  mounted  in 
accordance  with  the  requirements  described  in  this 
section. 
• The solar modules are in Application Class A and have 
the  Safety  Class  II.  Therefore,  they  can  be  operated  in 
systems with 120 V DC and higher.  General access is 
not restricted. 
• Any  module  without  a  frame  (laminate)  shall  not  be 
considered to comply with the requirements of UL 1703 
unless  the  module  with  hardware  that  has  been  tested 
and evaluated with the module under this standard or by 
a  field  inspection  certifying  that  the  installed  module 
complies with the requirements of UL 1703. 

 

Site Consideration 

LGE solar modules should be mounted in a location that 
meets the following requirements. 

Operating Temperature 

• Maximum Operating Temperature: +90

°

C (194

°

F) 

• Minimum Operating Temperature: -40

°

C (-40

°

F) 

Design Strength 

• LGE  solar  modules  are  certified  to  basic  loads         
50lb/ft2 (about 2400 Pa). 

Excluded Operating Environments 

• The  solar  modules  from  LG  Electronics  can  not  be 
operated  in  a  location  where  they  could  come  in  direct 
or indirect contact with salt water or ammonia.  

 

 

Mounting Methods 

General Information 

• Select the appropriate orientation to maximize sunlight 
exposure.  
• Module should not be mounted or stored in a way that 
the  front/top  glass  faces  downward  in  order  to  prevent 
water from entering the junction box, which could  cause  
a safety hazard.  
• Clearance  between  the  solar  module  frames  and 
structures such as roofs or ground is required to prevent 
wiring  damage  and  to  allow  air  to    circulate  behind  the 
solar  module.  The    recommended  standoff  height  is  a 
minimum of 100mm. 
• When  installed  on  a  roof,  the  solar  module  must  be 
mounted over a fire-resistant roof covering rated for the 
application.  The  fire  resistance  of  the  solar  module    is 
class C after ANSI/UL790.  
• The  solar  module  is  only  IEC  listed  for  use  when  its 
factory frame is fully intact. 
• Removal or alteration must be done by an authorized 
and qualified individual. 
• Creating  additional  mounting  holes  may  damage  the 
solar module and reduce the strength of the frame. 
• We  recommend  a  6mm  gap  between  module  frames  
to avoid tension from thermal expansion. 

 

The  fire  rating  of  this  module  is  valid  only  when 

mounted  in  the  manner  specified  in  the  mechanical 
mounting instructions. 

 

• The  module  is  considered  to  be  in  compliance  with 
UL1703  only  when  the  module  in  mounted  in  the 
manner specified by the mounting instructions below. 
• The solar module may be mounted by using the 
  following methods: (*Torque:8~12Nm )

 

 
 
Mounting by using frame bolts holes 

• Secure the solar module to the structure by using the 
factory mounting holes. 
• Four  M6  stainless  steel  bolts,  four  nuts,  four  spring 
washers,  and  eight  flat  washers  are  recommended  per 
solar module. 
• The  module  may  be  fastened  to  a  support  by  using 
both the outer and inner bolt holes of the frame. 
• Each  module  should  be  securely  fastened  at  a 
minimum 4 points on two opposite sides. 
• Specific  information  on  the  solar  module  dimensions 
and  location  of  mounting  holes  is  provided  in 

„Product 

Specifications‟.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 

• Tighten  the  bolt  securely  by  using    the  combination 
shown above. Place the spring washer between the Flat 
washer and Nut. 

 

Mounting by using clamps 

• The  module  may  be  fastened  to  a  support  by  using 
clamps on both the long edge and the short edge of the 
modules. 
• Specific  information  on  the  solar  module  dimensions 
and  location  of  clamping  is  provided  in 

„Product 

Specifications‟.  

 

Module frame 

Bolt 

Flat washer 

Flat washer 

Spring washer 

Nut 

Support 

Summary of Contents for LG S1C-G3 Series

Page 1: ...Monocrystalline Solar Module LGXXXS1C W K G3 ...

Page 2: ...1 Revisions Table Date Version Amendments Tech note 2012 08 01 1 0 1st edition Establish 2012 11 16 2 0 2nd edition Legality check ...

Page 3: ...e frame or glass of the module may decrease the strength of the frame or break the glass Do not touch the glass surface or frame of the solar module after installation of the module It may result in injury or death Heavy objects must be kept off of the solar module Do not stand on or step on the module Do not drop the module Failure to comply may result in product damage product failure or bodily ...

Page 4: ...ations are made at conditions of 1000W m2 irradiance and 25 C 77ºF solar cell temperature Colder temperatures may substantially increase voltage and power Keep the solar module and system away from children at all times Keep the module packed in the carton until the time of installation Keep flammable gasses away from the installation site Do not work alone Work as part of a team of two or more pe...

Page 5: ...d in series should be the same The maximum number of series connected modules can be determined by max system voltage the 125 safety factor not explained in specifications and the module Voc which can be checked in Product Specifications in this document Do not exceed 80 of maximum system voltage Maximum Module configuration recommend refer to the Product Specification in this manual Parallel Conn...

Page 6: ...e spring washer two flat washers one cup washer one star washer and 12 AWG Cu wires are recommended per mounting hole Where common grounding hardware nut bolts washers is used to attach a listed grounding device the attachment must be made in conformance with the grounding device manufacturer s instructions There is an earth hole on the edge of the module frame Using this hole an earth conductor a...

Page 7: ... of 100mm When installed on a roof the solar module must be mounted over a fire resistant roof covering rated for the application The fire resistance of the solar module is class C after ANSI UL790 The solar module is only IEC listed for use when its factory frame is fully intact Removal or alteration must be done by an authorized and qualified individual Creating additional mounting holes may dam...

Page 8: ...to the rooftop 2 Flat roof If installed with an additional stand such as wind shield or deflector Use four clamps on the long frame Use four mounting holes on two opposite sides Mounting Type Clamping Type Long Side Clamping Type Short Side LGXXXS1C W K G3 Clamping Range 230mm 270mm 270mm 7 Clamping Range From module Edge to 120mm Clamping Range From module Edge to 270mm Center 100mm Center 100mm ...

Page 9: ... 600 12 MC4 1640 1000 35 16 8 15 LG250S1C G3 Yes 250 3 38 26 8 62 30 77 8 13 46 0 2 0 420 4 5 600 12 MC4 1640 1000 35 16 8 15 LG255S1C G3 Yes 255 3 38 41 8 72 30 97 8 24 46 0 2 0 420 4 5 600 12 MC4 1640 1000 35 16 8 15 LG260S1C G3 Yes 260 3 38 56 8 82 31 17 8 35 46 0 2 0 420 4 5 600 12 MC4 1640 1000 35 16 8 15 LG265S1C G3 Yes 265 3 38 71 8 92 31 37 8 46 46 0 2 0 420 4 5 600 12 MC4 1640 1000 35 16 ...

Page 10: ... connected to installation operation or service of LG Solar Modules and if applicable from all liabilities claims demands losses or damages on my account caused or alleged to be caused in whole or in part by the negligence of the LG its affiliated companies successors or assigns its administrators directors agents officers volunteer and employees Disposal Please contact us if you have any queries ...

Page 11: ...om http www lgsolarusa com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws Document II G3 UL V2 EN 201211 10 ...

Reviews: