background image

8

Mechanical Installation

Mounting T

ype

Clamping T

ype

(Long Side)

Clamping T

ype

(Short Side)

105mm

105mm

150mm

50mm

150mm

50mm

Use four mounting holes on two opposite sides.

Use four clamps on the long frame.

Use four clamps on the short frame and

two clamps at the center of long frame.

Clamping Range

(100mm)

Clamping Range:

From module Edge

to 270mm

Clamping Range:

From module Edge

to 120mm

Center ± 100mm

Center ± 100mm

Use four clamps on the Short frame.

This method is not tested by IEC/UL.

This installation is allowed in the following cases: 
1. Slope roof: If module is installed parallel to the rooftop.
2. Flat roof: If installed with an additional stand such as wind shield

or deflector.

LGXXXN9C(W)-G4

Summary of Contents for LG280N1C-G4

Page 1: ...Monocrystalline Solar Module LGXXXN9C W G4 LGXXXN1C W K G4 Installation Instructions MFL69021104 ...

Page 2: ... Before After Installation 4 3 Electrical Installation 5 4 Mechanical Installation 6 5 Product Specifications 10 6 Disclaimer of Liability Disposal 12 7 Transporting and Storage 12 Date Version Remark Description of change 1 0 1st edition 2015 01 22 ...

Page 3: ...re Stralght type Product Deformation Occurrence of space Please use proper equipment connector wire and buttress for system configuration of the module It may result in damage or failure of the product Do not perform installation in rainy heavily windy or snowy days It may result in safety accident Do not make holes in the frame or glass of the module It may decrease the strength of the frame or b...

Page 4: ...to the stand away from the roof or ground Before Installation Please carefully read this manual before installation Solar module installation should be performed by an authorized installer for the safety and maintenance of the system All installation instructions should be clearly understood before attempting installation Do not twist pull or scratch the cable attached to the solar module Do not t...

Page 5: ...nd maintaining a panel Do not use panels of different electrical or physical configurations in the same system Match the polarities of cables and terminals when making the connections failure to do so may result in damage to the panel When reverse currents can exceed the value marked on the name plate a properly rated and certified over current device fuse or circuit breaker must be connected in s...

Page 6: ...ounted over a fire resistant roof covering rated for the application The fire resistance of the solar module from LG Electronics is class C after ANSI UL790 The solar module is only IEC listed for use when its factory frame is fully intact Do not remove or alter the solar module frame Creating additional mounting holes may damage the solar module and reduce the strength of the frame Electrical Ins...

Page 7: ...ping is provided in Mechanical Installation Scene Refer to next page Mounting by using frame bolts holes Secure the solar module to the structure using the factory mounting holes Four M6 stainless steel bolts four nuts four spring washers and eight flat washers are recommended per solar module For rear loads 5400Pa modules should be fastened with four M8 stainless steel bolts four nuts four spring...

Page 8: ...o clamps at the center of long frame Clamping Range 100mm Clamping Range From module Edge to 270mm Clamping Range From module Edge to 120mm Center 100mm Center 100mm Use four clamps on the Short frame This method is not tested by IEC UL This installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop 2 Flat roof If installed with an additional stand s...

Page 9: ...the center of long frame Clamping Range 250mm Clamping Range From module Edge to 270mm Clamping Range From module Edge to 120mm Center 100mm Center 100mm Use four clamps on the Short frame This method is not tested by IEC UL This installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop 2 Flat roof If installed with an additional stand such as wind ...

Page 10: ...ncy Reduction Max No of modules in ser es Max System Voltage Connector Length Width Height Weight W V A V A V mm mm mm kg g LGXXXN9C W G4 LG270N9C W G4 Yes 270 3 36 7 9 86 28 9 9 35 2 0 22 1000 MC4 1480 1000 40 15 4 LG275N9C W G4 Yes 275 3 36 8 9 90 29 3 9 39 2 0 22 1000 MC4 1480 1000 40 15 4 LG280N9C W G4 Yes 280 3 37 0 9 94 29 7 9 43 2 0 22 1000 MC4 1480 1000 40 15 4 L LG285N9C W G4 Yes 285 3 37...

Page 11: ... MC4 1640 1000 40 17 0 LG320N1C W G4 Yes 320 3 40 9 10 05 33 6 9 53 2 0 19 1000 MC4 1640 1000 40 17 0 L LG325N1C W G4 Yes 325 3 41 2 10 08 34 0 9 57 2 0 19 1000 MC4 1640 1000 40 17 0 LG330N1C W G4 Yes 330 3 41 5 10 11 34 3 9 63 2 0 19 1000 MC4 1640 1000 40 17 0 LG335N1C W G4 Yes 335 3 41 8 10 14 34 6 9 69 2 0 19 1000 MC4 1640 1000 40 17 0 LG340N1C W G4 Yes 340 3 42 1 10 17 34 9 9 75 2 0 19 1000 MC...

Page 12: ...should be disposed of separately from the municipal waste stream 2 Old electrical products can contain hazardous substances so correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to cons...

Page 13: ......

Page 14: ...ui daero Yeongdeungpo gu Seoul 150 721 Korea Contact solarinfo lge com http www lg solar com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws Document II G4 N IEC V1 EN 201501 ...