Safety 

The  instructions  related  to  the  safety  indicated  in 
the following are for preventing unexpected danger 
or damage in advance by safely and exactly using 
the product. 

 

Non-compliance  of  the  instructions  may  immedia-
tely cause serious injury or death. 

 

Non-compliance  of  the  instructions  may  cause 
death or serious injury to the user. 

 

Non-compliance  of  the  instructions  may  cause 
injury or property damage to the user. 

 

Do  not  contact  with  electrically  active  parts  of 

the  panel,  such  as  terminals,  regardless  of 
connection  of  the  module.  It  may  result  in  spark 
or lethal electric shock. 

Please  don’t  use  the  module  with  the  broken 

window  or  the  torn  back  side.  There  is  a  danger 
of electric shock

 

 

 

 

Please  perform  works  in  the  dry  condition  and 

use only dry tools. Do not handle the wet panels 
without  protection  equipment.  It  may  result  in 
safety accident. 

Damaged  module  must  be  treated  with  safety 

protection equipment. It may result in injury. 

Do not approach the damaged or broken module 

unless you are an expert. It may result in serious 
injury. 

No  electrical  parts  like  cables  are  located  after 

installation  between  laminate  and  mounting 
structure.  

Do  Not  reconnect  or  repair  Junction  box  Cable. 

It may occur spark or electric shock. 

 Do not bending junction box's cable. While  

     under stress, it may occur module damage.  
     Cable bending radius should be more than  
     4 times the cable diameter, at least. 

 

 

Please  use  proper  equipment,  connector,  wire 

and  buttress  for  system  configuration  of  the 
module. It may result  in damage  or failure  of the 
product. 

Do  not  perform  installation  in  rainy,  heavily 

windy  or  snowy  days.  It  may  result  in  safety 
accident. 

Do  not  make  holes  in  the  frame  or  glass  of  the 

module.  It  may  decrease  the  strength  of  the 
frame or break the glass. 

Do  not  touch  the  glass  surface  or  frame  of  the 

solar  module  after  installation  of  the  module.  It 
may result in injury. 

Do  not  locate  a  heavy  object  onto  the  module. 

Do  not  stand  on  or  step  on  the  module.  Do  not 
drop  or  suddenly  lay  down  the  module.  It  may 
result in injury. 

Do not scratch the coating surface of the frame. 

It  may  decrease  the  strength  due  to  corrosion  of 
the frame. 

Do  not  concentrate  sunlight  on  the  module 

surface. It may result in damage of the product. 

Do  not  apply  a  shock  to  the  junction  box  of  the 

module  or  pull  the  cable.  Do  not  remove  the 
labels  attached  to  the  module.  It  may  result  in 
damage of the product. 

If  the  installing  structure  has  a  curved  surface 

e.g.  arch type  as  shown  in  the  below  picture,  do 
not  forcefully  modify  the  module  in  installation 
when  connecting  it  with  the  structure.  Please 
install the module in the place where the structure 
has been completely set up because deformation 
of  the  structure  may  cause  deformation  of  the 
product  when  performing  installation  by  using  a 
crane,  etc  after  assembling  the  module  to  the 
installing structure. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for LG330N1C-A5

Page 1: ...ully before operating your set and retain it for future reference www lg solar com Installation manual PV Solar MODULE P NO MFL69654303 Rev 01 P TYPE MODELS LGXXXS1C W A5 LGXXXS2W A5 W5 N TYPE MODELS LGXXXN1C W K A5 LGXXXN2C W K A5 ...

Page 2: ...t Specifications 8 6 Disclaimer of Liability Disposal 11 7 Transporting and Storage 11 8 Appendix 12 Revisions Table Date Version Description of change Remark 2016 09 27 1 0 1st edition 2016 11 30 2 0 Add N Type Products 2017 01 10 3 0 Add P Type Product 302W Edit to Modules CAD Drawings 2 2017 03 22 4 0 Add P Type Product W5 Model ...

Page 3: ...Cable bending radius should be more than 4 times the cable diameter at least Please use proper equipment connector wire and buttress for system configuration of the module It may result in damage or failure of the product Do not perform installation in rainy heavily windy or snowy days It may result in safety accident Do not make holes in the frame or glass of the module It may decrease the streng...

Page 4: ...in the carton until the time of installation Make sure flammable gases are not generated near the installation site Do not work alone Please work as part of a team of two or more people Wear a safety belt if working high above the ground Contact with electrically active parts of the panels such as terminals can result in burns sparks and lethal shock whether the panel is connected or disconnected ...

Page 5: ...duce the desired voltage output The current of each module connected in series should be same The maximum number of series connected modules can be determined by basis on max system voltage the 125 safety factor and the module Voc which can be checked in Product Specifications in this document The maximum solar module configuration can be found in Product Specifications Series connection for more ...

Page 6: ...ar washer Cup washer Grounding wire Spring washer Nut Flat washer 6 Module Mounting The LG Electronics LGE Limited Warranty for solar modules is contingent upon modules being mounted in accordance with the requirements described in this section The solar modules are in Application Class A and have the Safety Class II Therefore they can be operated in systems with 120 V DC and higher General access...

Page 7: ... bolts holes Secure the solar module to the structure using the factory mounting holes Four M8 stainless steel bolts four nuts four spring washers and eight flat washers are recommended per solar module The module may be fastened to a support using both the outer and inner bolt holes of the frame Each module should be securely fastened at a minimum 4 points on two opposite sides Specific informati...

Page 8: ...Yes 315 39 8 10 22 32 7 9 64 20 20 1000 MC4 JM601A 1686 1016 40 18 0 LG320S1C W A5 Yes 320 40 1 10 27 33 1 9 68 19 20 1000 MC4 JM601A 1686 1016 40 18 0 LG335S2W A5 W5 Yes 335 45 8 9 86 36 0 9 31 17 20 1000 MC4 JM601A 2024 1024 40 21 7 LG340S2W A5 W5 Yes 340 45 9 9 91 36 4 9 35 17 20 1000 MC4 JM601A 2024 1024 40 21 7 LG345S2W A5 W5 Yes 345 46 1 9 96 36 7 9 41 17 20 1000 MC4 JM601A 2024 1024 40 21 7...

Page 9: ... m2 Cell temp 25 1 5AM LGXXXN1C W A5 LGXXXN1K A5 LG360N2C W A5 LG365N2C W A5 LG370N2C W A5 LG375N2C W A5 LG380N2C W A5 LG385N2C W A5 LG390N2C W A5 LG395N2C W A5 LG400N2C W A5 Yes 360 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 48 5 10 19 37 4 9 63 16 20 1000 MC4 JM601A 05 8 2024 1024 40 21 7 Yes 365 48 6 10 19 37 8 9 66 16 20 1000 MC4 JM601A 05 8 2024 1024 40 21 7 Yes 3...

Page 10: ...Product Specifications Dimensions of Modules 10 60Cell Module 72Cell Module Unit mm in ...

Page 11: ... stream 2 Old electrical products can contain hazardous substances so correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to conserve limited resources 3 You can take your appliance eith...

Page 12: ...Fig 6 Clamping Type A B B A C C B A 4 point installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop d n i w s a h c u s d n a t s l a n o i t i d d a n a h t i w d e l l a t s n i f I f o o r t a l F 2 A 200mm B 400mm Front 6000Pa Rear 5400Pa m m 0 2 1 A 4point Front 1800Pa Rear 1800Pa C 120mm Front 3200Pa Rear 1800Pa A 120mm m m 0 0 1 3 4 8 B 6po...

Page 13: ...C C B A 4 point installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop d n i w s a h c u s d n a t s l a n o i t i d d a n a h t i w d e l l a t s n i f I f o o r t a l F 2 A 250mm B 400mm Front 5400Pa Rear 4300Pa m m 0 2 1 A 4point Front 1600Pa Rear 1600Pa C 120mm Front 3200Pa Rear 1600Pa A 120mm m m 0 0 1 12 0 1 B 6point Front 5400Pa Rear 4300P...

Page 14: ...st Fig7 Bolting Type 812mm Front 2000Pa Rear 1750Pa Note When installed Fig 7 follow the tracker manufacturer s recommended applied torque and materials to fasten Only Tracker Module frame Bolt Flat washer Flat washer Spring washer Nut Mounting Rail Four M8 5 16inch stainless steel bolts four nuts four spring washers and eight flat washers are recommended per solar module Bolting Method the module...

Page 15: ...oui daero Yeongdeungpo gu Seoul 150 721 Korea Contact solarinfo lge com http www lg solar com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws Document II A5 IEC V4 EN 201609 ...