7-8
D. REMOVING MAGNETRON
(Figures 11 Through 12)
(1) Remove the vent grille by loosening two screws.
(Figure 11)
(2) Remove the outcase. See page 7-6.
(3) Remove four tap tite screws securing the
magnetron to the wave guide.
(4) Disconnect the leadwire.
(5) Remove the magnetron VERY CAREFULLY.
NOTES:
• When removing the magnetron, make sure that its
dome does not hit any adjacent parts, or it may be
damaged.
• When replacing the magnetron, be sure to install the
magnetron gasket in the correct position and be sure
that the gasket is in good condition.
• After replacing the magnetron, check for microwave
energy leakage with a survey meter Check
microwave energy leakage must be below the limit
of 5 mW/cm
2
. (All service adjustments should be
made for minimum microwave energy leakage
readings.)
E. REMOVING STIRRER FAN
(Figures 13 and 14)
(1) Remove one rivet ASS'Y securing it to the oven
upper plate by using knife blade.
(2) Remove the stirrer fan cover.
(3) Remove the stirrer fan.
Magnetron
Figure 12
Figure 11
Figure 13
Figure 14
Summary of Contents for LMV1630BB
Page 7: ...4 1 OPERATING INSTRUCTIONS CONTROL PANEL ...
Page 9: ...5 1 OVERALL CIRCUIT DIAGRAM SCHEMATIC DIAGRAM ...
Page 10: ...5 2 MATRIX CIRCUIT FOR TOUCH KEY BOARD KEY MATRIX ...
Page 34: ...7 23 PROBLEM F No buzzing when touching the key between stages or at end of cooking 1 ...
Page 40: ...8 5 LATCH BOARD PARTS 43501A WSZ085 43500A 466001 466003 466001 44510A EV ...