7-2-4 Function TEST
1. This is a forced operation for TEST, Service, cleaning, etc. It is operated by pressing and holding the Fill Key for 3 seconds.
2. The test works only in the Icemaking Mode. It cannot be entered from the Harvest or Fill mode.
3. Caution! If the test is performed before water in the icemaker is frozen, the ejector will pass through the water. When the
Fill mode begins (Stage 4), unless the water supply has been shut off, added water will overflow into the ice bin. If the
control doesn’t operate normally in the TEST mode, check and repair as needed.
4. After water is supplied, the normal CYCLE is followed: icemaking
→
Harvest
→
Park Position
→
Fill.
5. Five seconds after Stage 5 is completed, the Ice Maker returns to MICOM control. The time needed to supply water
resets to the pre- test setting.
Diagnosis TABLE
7-3 DEFECT DIAGNOSIS FUNCTION
7-3-1 ERROR CODES shown on Ice Maker water supply control panel
- 27 -
STAGE
ITEMS
INDICATOR
REMARKS
1
2
3
4
5
6
HEATER
MOTOR
HALL IC
I
HALL IC
II
VALVE
Reset
Five seconds after heater starts, a
heater will go off if the temperature by
sensor is higher than 10°C
Five seconds after heater starts, you
can confirm that a motor is moving.
Check if Ice Bin is full or not.
If Ice bin is full, the motor and heater
are off and on stand by until Ice bin is empty.
You can confirm HALL IC detection of start
position.
Two seconds after detection of start position,
you can confirm that valve is on.
Five seconds after fifth stage is completed,
The icemaker resets to initial status.
Return to Status prior to
TEST MODE
NO
DIVISION
INDICATOR
CONTENTS
REMARKS
1
2
Normal
Icemaking
Sensor
malfunction
Mark time to
supply
None
Open or short-circuited wire
Display switch
operates properly
Make sure that the wire
on each sensor is
connected.