9
-1-9 Defect Diagnosis Function
1. Automatic diagnosis makes servicing the refrigerator easy.
2. When a defect occurs, the buttons will not operate; but the tones. such as ding. will sound.
3. When the defect CODE removes the sign, it returns to normal operation (RESET).
4. The defect CODE shows on the Refrigerator and Freezer Display.
ERROR CODE on display panel
- 47 -
Defect code signs
Defect code signs
ADJUST
WARMER
REFRIGERATOR TEMP
FREEZER TEMP
4 IS RECOMMENDED
COLDER
EXPRESS
FREEZING
ADJUST
WARMER
4 IS RECOMMENDED
COLDER
NO
ITEM
ERROR CODE
CONTENTS
REMARKS
1
2
3
4
Failure of freezer
sensor
Failure of
Refrigerator sensor
Failure of defrost
sensor
Poor of defrost
Cut or short circuit wire
Cut or short circuit wire
Cut or short circuit wire
2hours later After
starting defrost, If
sensor doesn’t be over
46°F (8°C)
Inspect Connecting
wires on each sensor
Snapping of defrost
heater or Temperature
fuse, pull-out of
Connector (indicated
minimum 2 Hours
after failure occurs)
All off
All off
All off
All off
LED OFF
LED ON
Summary of Contents for LRBC22522
Page 12: ...GY GRIS GRAY Best Best dispenser 5 CIRCUIT DIAGRAM 12 ...
Page 13: ...GY GRIS GRAY Good Better 13 ...
Page 40: ...8 5 MAIN PWB ASSEMBLY AND PARTS LIST 8 5 1 Main PWB Assembly 40 ...
Page 41: ...8 5 2 Replacement Parts List 41 ...
Page 42: ...8 5 3 PWB Assembly Display And Parts List 42 SW106 Dispenser Model Best Model ...
Page 60: ...9 5 MAIN PWB ASSEMBLY AND PARTS LIST 9 5 1 Main PWB Assembly 60 ...
Page 61: ...9 5 2 Replacement Parts List 61 ...
Page 62: ...9 5 3 PWB Assembly Display And Parts List 62 ...
Page 63: ...9 6 PWB DIAGRAM 9 6 1 PWB Main Assembly 63 G5S 1A RY5 ...
Page 64: ... 64 ...
Page 70: ...June 2009 ...